56
5-17
5-18
5-18b
5-19
1
(WAP)
5-20
1
Operation
5.9 Weight application
The following weight types and application
methods are available:
- Clip-on weights.
•
Always apply by hand at 12 o’clock (
Figure
5-17
).
•
The tab should be fi tted on the rim edge. Use the
weight pliers to correctly position it.
- Stick-on weights.
•
Apply with arm gauge, in case of Alu 1P, Alu 2P and
Alu 3P (
Figure 5-18
).
•
Apply by hand at 12 o’clock in all other cases
(
Figure 5-18b
).
Note:
With STATIC balancing mode, always apply
the weight at 12 o’clock on the rim centre line. If
not possible, split the weights evenly and apply on
another surface of the rim (symmetrical to the rim
centre line).
Note:
In STATIC balancing mode, only the left
hand display is used (
1,Fig. 5-19
).
After spinning the wheel look at the rotation indicators
for the left plane of the wheel (
1, Fig. 5-20
):
•
Turn the wheel manually until it reaches the
counterweight application point;
Arrows above and below, completely green.
..
Summary of Contents for B 200