JetMove 225-480
11 Analog Input (Option)
Jetter AG
89
11
Analog Input (Option)
11.1
Function
For the digital servo amplifier JetMove 225-480, an optional integrated analog input
card can be ordered (article designation of the device: JM-225-480...-IA1). This card
supplies an analog input of a 12-bit resolution. The converted value of the measured
voltage can be read by a register of the JetMove in the PLC program or processed
by the firmware of the JetMove in an additional controller. This way it is possible for
example, to realize a pressure control loop in which the motor controlled by the
JetMove generates the pressure. A pressure sensor in the machine is connected to
the analog input of the JetMove to deliver the actual pressure value for the control
loop.
11.2
Technical Data
Technical Data for the Analog Input
Type of connection
SUB-D-connector (male) at the device
Voltage range
0 ... 10 V
Input current
1.4 mA max.
Resolution
12 bits
Value range
0 ... 32.767 (resolution in steps of 8)
Electrical isolation
none
Accuracy
Offset error
Gain error
max. ± 5 LSB (± 40 values), correspond to ± 12.2 mV
max. ±
10 LSB (± 80 values), correspond to ± 24.4 mV
Summary of Contents for JetMove 225-480
Page 1: ...JetMove 225 480 Digital Servo Amplifier 60874967...
Page 24: ...1 Safety Instructions JetWeb 24 Jetter AG...
Page 36: ...4 Mounting Dimensions JetWeb 36 Jetter AG...
Page 44: ...5 Technical Data JetWeb 44 Jetter AG...
Page 76: ...7 Description of Connections JetWeb 76 Jetter AG...
Page 84: ...JetWeb 84 Jetter AG...
Page 88: ...JetWeb 88 Jetter AG...
Page 116: ...15 Ordering Information JetWeb 116 Jetter AG...
Page 117: ...JetMove 225 480 Appendix Jetter AG 117 Appendices...
Page 118: ...Appendices JetWeb 118 Jetter AG...