JetWeb
46
Jetter AG
Drive controller specification
All drive controllers can be parameterized through the control program.
Function
Meaning
Motor control
(commutation)
Space vector
modulation
PWM frequency
8 kHz
Current controller
– Cycle time
62.5 µs
Speed controller
– Cycle time
– Current pre-control
125 µs
adjustable
Position feedback controller
– Cycle time
– Speed pre-control
250 µs
adjustable
Position setpoint generator
– Sine-square and linear acceleration and
deceleration ramps
– Setpoint output cycle (position feedback controller
interpolation)
can be parameterized
individually
2 ms
Position sensing
Resolver:
– Resolution
– Sampling interval T
Sine-cosine sensor
(multi- and single-turn):
– Interface
– Resolution of absolute position
– Resolution of velocity pickup
– Sampling interval T
12 bits per revolution
62.5 µs
HIPERFACE
15 bits per revolution
20 bits per revolution
62.5 µs