JetMove 225-480
14.1 Function
Jetter AG
107
14
Counting Input (Option)
14.1
Function
For the JetMove 225-480, an optional integrated counter card can be ordered (article
designation of the device: JM-225-480...-CNT). It supplies a counting input equipped
with the following interface:
• EnDat 2.2 by Heidenhain
• Synchronous Serial Interface (SSI)
• Incremental counter
The received or counted value of an actual position can be read via a JetMove
register by the controller program or processed by the firmware of the JetMove in the
controllers.
14.2
EnDat 2.2
14.2.1 Technical data
Technical Data of the Input EnDat 2.2
Encoder types
Single-, multiturn, or linear absolute encoders
Scanning
62.5 µs
Baud rate
8 MHz
Maximum cable length
100 m
Type of signal
5 V differential signals
Input impedance
22 k
Bus termination
120
integrated resistance
Electrical isolation
none