3 Operating Conditions
Jetter AG
33
Additional line filters can be helpful here. See "Line filter" on page 38.
EMC
Emitted Interference
Parameter
Value
Reference
Enclosure
• Frequency band
30 - 230 MHz, limit 30 dB (
V/m)
at 30 m
• Frequency band
230 - 1,000 MHz, limit 37 dB
(
V/m) at 30 m
(class B)
DIN EN 61800-3
Mains alternating
current
• Frequency band
0.15 - 0.5 MHz, limit 79 dB (
V)
• Frequency band
0.5 - 30 MHz, limit 73 dB (
V)
DIN EN 61800-3
Important!
This product comes under category C2 to DIN EN 61800-3.
This module can cause radio interferences in residential areas; in this
case, the user has to take adequate measures to prevent this.
EMC
Immunity: Enclosure
Parameter
Wert
Bezug
RF field, amplitude-
modulated
Frequency band 80 -
1,000 MHz; test field strength
10 V/m
AM 80 % with 1 kHz
Criterion A
DIN EN 61000-4-3
DIN EN 61800-3
ESD
Contact discharge:
Test peak voltage 6 kV
Criterion B
DIN EN 61800-3
DIN EN 61000-4-2