3 Operating Conditions
JetWeb
34
Jetter AG
Immunity: Power Connections and Power Interfaces
Parameter
Value
Reference
Conducted radio
disturbances
Frequency 0.15 - 80 MHz
Test voltage 10 V
AM 80 % with 1 kHz
Criterion A
DIN EN 61800-3
DIN EN 61000-4-6
Burst (fast transients)
Test voltage 2 kV
tr/tn 5/50 ns
Repetition frequency 5 kHz
Criterion B
DIN EN 61800-3
DIN EN 61000-4-4
Impulse voltages
tr/th 1.2/50 µs, 8/20 µs
1 kV (phase to phase)
2 kV (phase to ground)
Criterion B
DIN EN 61800-3
DIN EN 61000-4-5
Immunity: Process, Measuring and Control Lines
Parameter
Value
Reference
Conducted radio
disturbances
Frequency 0.15 - 80 MHz
Test voltage 10 V
AM 80 % with 1 kHz
Criterion A
DIN EN 61800-3
DIN EN 61000-4-6
Burst (fast transients)
Test voltage 2 kV
tr/tn 5/50 ns
Repetition frequency 5 kHz
Criterion B
DIN EN 61800-3
DIN EN 61000-4-4
Immunity: Signal Interfaces
Parameter
Value
Reference
Conducted radio
disturbances
Frequency 0.15 - 80 MHz
Test voltage 10 V
AM 80 % with 1 kHz
Criterion A
DIN EN 61800-3
DIN EN 61000-4-6
Burst (fast transients)
Test voltage 1 kV
tr/tn 5/50 ns
Repetition frequency 5 kHz
Criterion B
DIN EN 61800-3
DIN EN 61000-4-4
EMC
Summary of Contents for JetMove 225-480
Page 1: ...JetMove 225 480 Digital Servo Amplifier 60874967...
Page 24: ...1 Safety Instructions JetWeb 24 Jetter AG...
Page 36: ...4 Mounting Dimensions JetWeb 36 Jetter AG...
Page 44: ...5 Technical Data JetWeb 44 Jetter AG...
Page 76: ...7 Description of Connections JetWeb 76 Jetter AG...
Page 84: ...JetWeb 84 Jetter AG...
Page 88: ...JetWeb 88 Jetter AG...
Page 116: ...15 Ordering Information JetWeb 116 Jetter AG...
Page 117: ...JetMove 225 480 Appendix Jetter AG 117 Appendices...
Page 118: ...Appendices JetWeb 118 Jetter AG...