DIAGNOSTICS & TROUBLESHOOTING
Jenn-Air Built-in Coffee System
n
5-15
For Service Technician Use Only
DIVERTER LIMIT SWITCHES
MAIN BOARD
J4-1
J5-1
J4-3
J5-2
SWITCH, M1
MAIN BOARD
SWITCH, M2
UPPER DIVERTER POSITION
(located on top of diverter ass’y )
LOWER DIVERTER POSITION
(located behind diverter motor)
W
W
W
W
VDC
VDC
DIVERTER MOTOR
DIVERTER
MOTOR
MAIN BOARD
62
FILTER
J1-3
J1-5
M
140 VDC *
Relay 1
Relay 2
* DC Voltage polarity reverses
to drive motor up & down.
GND *
BK
R
L1
MAIN BOARD
N
458k
ON/OFF
SWITCH
ON/OFF
SWITCH
EV1 SWITCH
EV1
3-WAY VALVE
CHASSIS GND
L1
TERMINAL
BLOCK
3-WAY VALVE
J1-2
F5
NOTE: 2-way valve is grounded
to heat exchanger support.
BK
BK
BK
R
W
W
L1
MAIN BOARD
N
444k
ON/OFF SWITCH
ON/OFF
SWITCH
EV2 SWITCH
EV2
2-WAY VALVE
CHASSIS GND
L1
TERMINAL
BLOCK
2-WAY VALVE
J1-1
F5
NOTE: 2-way valve is grounded to heat
exchanger support, lower and upper
control cover, and upper reinforcement.
BK
BK
BK
BR
W
W
Strip Circuits
DIVERTER ASSEMBLY
VALVE ASSEMBLIES
3-Way Valve
2-Way Valve
Diverter Limit Switches
Diverter Motor