4-16
n
Jenn-Air Built-in Coffee System
COMPONENT ACCESS
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Removing the Diverter/Transmission Assembly
1.
Remove back panel (page 4-10) to access Diverter/
Transmission Assembly.
2.
Open service door to access Infuser assembly. Remove
drip tray from coffee system.
Figure 1
3.
Press in on the red clips on each side of the Infuser
assembly and then pull the infuser out of the coffee
system (see Figure 2).
Figure 2
4.
Next, remove the two (2) Allen bolts and take out the
infuser holder. Then, remove the single screw in the
diverter pivot. (See Figure 3.)
Figure 3
5.
Disconnect the data, motor, and sensor cables (see Figure
4). Remove the diverter/transmission assembly from
coffee system.
Figure 4
continued...
Infuser Holder
Pivot Screw