Removing the Flow Meter
1.
Remove back panel (page 4-10) to access flow meter
assembly (see Figure 1).
Figure 1
2
. Unscrew the screw to remove the electrical cable bracket
(see Figure 2). Set aside to access the flow meter.
Figure 2
3.
Lift off the rubber cap to access the flow meter connector.
Remove harness from flow meter (see Figure 3).
4.
Remove the two (2) water tubes from the flow meter (see
Figure 3).
Figure 3
Rubber Cap