JCM Part No. 960-000097R_Rev. 3
© 2010, JCM American, Corporation
2 - 2
Section 2
Universal Bill Acceptor (UBA-1x-SS & UBA-x4-SS/SU)
Installation/Operation
–
If the red chip LED is OFF, check
connections and make sure power is
applied.
–
If any of the indicator LEDs are ON,
check error codes to fix the problem.
6. Check operation by inserting banknotes of
each denomination to verify that the notes
are accepted and properly credited by the
host machine.
Lock Installation
One or two security locks can be installed onto a
UBA Cash Box. When installing a security lock,
the following attachment accessories may be
required:
1. Two key spacers
2. Plate lock keys and
3. A key cap attachment.
Dimensions of the Plate Key Lock is illustrated in
Figure 2-5.
Choose a Lock that fits a standard 5/8" or 1-1/8"
hole dimension format, because they are the only
formats supported. Use a key spacer if
required.When using only one lock, the remaining
blank hole does not provide access to Cash Box
contents. However, some regulatory authorities
may require installation of a key cap.
DIP Switch Configurations
Table 2-1 lists the default DIP Switch configura-
tions for the UBA Front panel DIP Switch Block.
Figure 2-5
Plate Key Lock Dimensions & Location
NOTE: When two locks are installed, they
must rotate in the same direction as
illustrated in Figure 2-6.
NOTE: There are many lock designs, and
key spacer washers may be required for
some lock types. Locks vary greatly in
price, security, keying policies, et cetera.
The customer is responsible for selecting a
lock with performance that fits the intended
purpose. JCM does not test or endorse any
specific brand of lock for its security
characteristics.
Table 2-1
DIP Switch Settings
UBA Front Panel Switches
Default Setting = ALL Switches are OFF
Switch
No.
Switch ON
Switch OFF
1
TITO
*
barcode
coupon disabled
*. TITO = Ticket In Ticket Out
TITO
*
barcode
coupon enabled
2
$1 Banknote
disabled
$1 Banknote
enabled
3
$5 Banknote
disabled
$5 Banknote
enabled
4
$10 Banknote
disabled
$10 Banknote
enabled
5
$20 Banknote
disabled
$20 Banknote
enabled
6
$50 Banknote
disabled
$50 Banknote
enabled
7
$100 Banknote
disabled
$100 Banknote
enabled
8
TEST Mode
NORMAL Mode
Figure 2-6
Key Lock Rotation Requirement
NOTE: DIP Switch settings may vary
based on software changes related to the
specific country using the UBA.
Please
contact your local JCM Customer
Representative for the latest setting
information, or visit the JCM Website at
www.jcmglobal.com.