4-52
4.12.2 Setting a vessel speed alert
When the vessel speed reaches the set range, the alert is issued.
The range can be selected from OVER, UNDER, IN RANGE, and OUTRANGE.
OVER:
An alert is issued when the vessel speed reaches or exceeds the set speed.
UNDER:
An alert is issued when the vessel speed is equal to or slower than the set speed.
IN RANGE:
An alert is issued when the vessel speed is between the lower limit value and the upper limit
value.
OUT RANGE: An alert is issued when the vessel speed is equal to or slower than the lower limit value
or equal to or higher than the upper limit value.
For IN RANGE and OUT RANGE, set the upper limit value and lower limit value.
1. Refer to "4.15.1 Change to a maintenance mode" and display the maintenance menu.
2. Select “ALARM” and “SPEED” in this order by using
.
3. Select “OVER, “UNDER”, “IN RANGE”, or “OUT RANGE” by using
.
4. Select “OVER, “UNDER”, “MAXIMUM” or “MINIMUM” by using
.
5. Enter a vessel speed by using
and press
.
6. Set an buzzer sound and screen back light by referencing "4.12.8 Setting a buzzer sound and
screen back light”.
4.12.3 Setting a TRIP alert
An alert is issued when the TRIP distance exceeds the set TRIP distance.
1. Refer to "4.15.1 Change to a maintenance mode" and display the maintenance menu.
2. Select “ALARM” and “TRIP” in this order by using
.
3. Select “OVER” by using
.
4. Select “OVER” by using
.
5. Enter a TRIP distance by using
and press
.
6. Set an buzzer sound and screen back light by referencing "4.12.8 Setting a buzzer sound and
screen back light”.
4.12.4 Setting ARRIVAL/ANCHOR Alert
An alert occurs when own ship reaches or leaves the arrival circle set on the route.
Alerts cannot be set for both reaching and leaving.
1. Refer to "4.15.1 Change to a maintenance mode" and display the maintenance menu.
2. Press
the
key to select "ALARM" and "ARRIVAL/ANCHOR" in order.
3. Press
the
key to select "OFF," "ARRIVAL," or "ANCHOR," and press the
key.
4. Set an buzzer sound and screen back light by referencing "4.12.8 Setting a buzzer sound and
screen back light”.
Procedure
Procedure
Procedure
Summary of Contents for JLR-7900
Page 2: ......
Page 11: ...ix...
Page 16: ......
Page 23: ...1 7 NBD 577C Power Supply Outline Drawing Unit mm Mass Approximately 5 4 kg...
Page 27: ...1 11 NQA 4351 Output Buffer Outline Drawing Unit mm Mass Approximately 0 8 kg...
Page 29: ...1 13 NCZ 1663 Select Switch Unit mm Mass Approximately 0 2 kg...
Page 30: ...1 14 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg...
Page 31: ...1 15 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg...
Page 33: ...1 17 NKG 94 Printer Outline Drawing Unit mm Mass 2 2 kg or less Printer Rack...
Page 38: ...2 4...
Page 42: ...3 4...
Page 138: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more...
Page 158: ...6 30...
Page 160: ...7 2...
Page 162: ...8 2...
Page 181: ......
Page 182: ......
Page 183: ......