4-16
4.3.6.1
Setting the Track Period
Memory intervals can be set to units of time or of distance.
The following periods can be set:
Time:
Can be set in 1 second increments between 1 second to 60 minutes.
Distance: Can be set in 0.01 NM increments between 0.01 to 99.99 NM.
1. Press
the
key to display the main menu.
2. Press
the
key to select "PLOT" and "TRACK PERIOD" and press the
key.
3. Press
the
to select "TIME" or "DISTANCE" and press the
key.
4. Press
the
key to enter the period.
If the period is set to "OFF," track memory will be deactivated. Previously stored data will be
retained.
4.3.6.2 Deleting
Tracks
All tracks can be deleted.
Partial deletion cannot be performed.
1. Press
the
key to display the main menu.
2. Press
the
to select "PLOT" and "TRACK ERASE" and press the
key.
3. When the following popup is displayed, press “YES”.
4.3.7 Waypoint Symbol and Route Display
The symbols and numbers of waypoints registered in the waypoint list are displayed on the plot
screen.
When navigation is performed, the route and the waypoint are displayed on the plot screen.
Procedure
Procedure
Waypoint
Waypoint No
Route No
Route
DELETE OK
?
YES NO
Supplement
Summary of Contents for JLR-7900
Page 2: ......
Page 11: ...ix...
Page 16: ......
Page 23: ...1 7 NBD 577C Power Supply Outline Drawing Unit mm Mass Approximately 5 4 kg...
Page 27: ...1 11 NQA 4351 Output Buffer Outline Drawing Unit mm Mass Approximately 0 8 kg...
Page 29: ...1 13 NCZ 1663 Select Switch Unit mm Mass Approximately 0 2 kg...
Page 30: ...1 14 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg...
Page 31: ...1 15 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg...
Page 33: ...1 17 NKG 94 Printer Outline Drawing Unit mm Mass 2 2 kg or less Printer Rack...
Page 38: ...2 4...
Page 42: ...3 4...
Page 138: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more...
Page 158: ...6 30...
Page 160: ...7 2...
Page 162: ...8 2...
Page 181: ......
Page 182: ......
Page 183: ......