4.15.7 Setting Contact Output
The following contact outputs can be set for contract output: Log Pulse (200 pulse/NM), Log Pulse
(400 pulse/NM), and Alert.
An overview of the contact output submenu is as follows.
1) LOG(200p/NM): 200 pulse/NM log pulse is output.
2) LOG(400p/NM): 400 pulse/NM log pulse is output.
3) ALARM:
Operates as a contact alert when an alert has been generated.
4) OFF:
Not
operate.
1. Refer to "4.15.1 Change to a maintenance mode" and display the maintenance menu.
2. Press
the
key to select "INTERFACE," "DATA I/O," and "CONTACT OUTPUT" in order.
3. Press
the
key to select the state for which you want contact operation, and press the
key.
4.15.8 Outputting Alert history
Alert history can be output to an external unit.
Data is output from a data IN/OUT1 port.
If data IN/OUT1 is set to reception, the port must be set to transmission.
Connect PC to a serial port before output operation.
1. Refer to "4.15.1 Change to a maintenance mode" and display the maintenance menu.
2. Refer to "4.15.5.1 Setting transmissin" to set DATA IN/OUT1 to "SEND."
3. Press
the
key to select "INTERFACE" and "DIAGNOSIS" in order.
4. Select "ERROR LOG OUT" and press the
key. Alert history is output to an external unit.
4.15.9 Checking installation
Installation can be checked.
The following items can be checked.
1) Checking the input port
2) Self-diagnosis
3) Display of alert history
4) Confirmation of software version and serial number
Procedure
When DATA IN/OUT1 is used by setting to transmission, port setting is not required.
The alert history is outputted between normal output sentences.
Supplement
See “4.15.8 Outputting alert history” for external output of alert history.
See "4.15.14 Outputting Setting value" for external output of setting value.
See “4.15.11 Demonstration” for setting a demo mode for confirmation of data output.
Supplement
Procedure
Summary of Contents for JLR-7900
Page 2: ......
Page 11: ...ix...
Page 16: ......
Page 23: ...1 7 NBD 577C Power Supply Outline Drawing Unit mm Mass Approximately 5 4 kg...
Page 27: ...1 11 NQA 4351 Output Buffer Outline Drawing Unit mm Mass Approximately 0 8 kg...
Page 29: ...1 13 NCZ 1663 Select Switch Unit mm Mass Approximately 0 2 kg...
Page 30: ...1 14 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg...
Page 31: ...1 15 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg...
Page 33: ...1 17 NKG 94 Printer Outline Drawing Unit mm Mass 2 2 kg or less Printer Rack...
Page 38: ...2 4...
Page 42: ...3 4...
Page 138: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more...
Page 158: ...6 30...
Page 160: ...7 2...
Page 162: ...8 2...
Page 181: ......
Page 182: ......
Page 183: ......