6-2
6.1
GPS Sensor Installation
6.1.1 Selecting the Position for Installation
When connecting the cable attached to the sensor, do not bend it acutely, twist it, or
impart excessive force. Doing so sometimes causes cracks or damage to the
coating, resulting in fire or electric shock.
Do not install the sensor where there is excessive vibration.
Vibration may cause sensor failure.
Do not paint the sensor.
Doing so may result in reception problems.
Do not install the sensor where temperature exceeds 55
C and there is covered
with exhaust gas from funnel.
Doing
so may result in equipment failure or malfunction.
The junction box rubber gaskets (25 f Gland side) fit
10mm - 20mm cables.
Install the sensor where there are no obstacles, in order to ensure that GPS signals
can be directly received from satellites without interference or reflection of signals
from surrounding objects.
Whenever possible, select a place with the following characteristics.
If it is difficult to find an ideal site, select a place temporarily and install the equipment.
Conduct a test to make sure that the proper performance can be obtained and then fix the
equipment in position. If it is installed at an improper place, reception accuracy may be
impaired.
To connect the sensor other than JLR-4341/4340, set the supply voltage of the display
unit to 12 VDC (10.8 to 15.6 VDC) for use. Failure to do so causes fire, electric shock or
failure.
1. An open space, which allows uniform reception of satellite signals.
2. Far away from any high power transmission antennas.
3. Outside radar beams.
4. Away from the INMARSAT antenna by at least 5 meters and outside the
INMARSAT beam.
5. Away from the antenna of a VHF transmitter and a direction finder by at least 3
meters.
6. Away from a Magnetic Compass by at least 1 meters.
7. Away from amateur radio antennas by at least 3 meters.
WARNING
CAUTION
Summary of Contents for JLR-7900
Page 2: ......
Page 11: ...ix...
Page 16: ......
Page 23: ...1 7 NBD 577C Power Supply Outline Drawing Unit mm Mass Approximately 5 4 kg...
Page 27: ...1 11 NQA 4351 Output Buffer Outline Drawing Unit mm Mass Approximately 0 8 kg...
Page 29: ...1 13 NCZ 1663 Select Switch Unit mm Mass Approximately 0 2 kg...
Page 30: ...1 14 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg...
Page 31: ...1 15 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg...
Page 33: ...1 17 NKG 94 Printer Outline Drawing Unit mm Mass 2 2 kg or less Printer Rack...
Page 38: ...2 4...
Page 42: ...3 4...
Page 138: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more...
Page 158: ...6 30...
Page 160: ...7 2...
Page 162: ...8 2...
Page 181: ......
Page 182: ......
Page 183: ......