JIF-2002 WEIGHING INDICATOR&CONTROLLER
10
3-1 Analog Input and A/D Conversion
◎
Analog Input and A/D Conversion
Type JIF-2002
Input Sensitivity
≧
0.3uV/D
ZERO Adjustment
Range
0 ~20mV
Load Cell Excitation
DC10V
±
1%
,
230mA, Remote Sensing.
Can be connected up to 8 350
Ω
Load Cells
Non-Linearity
0.01 % F.S.
A/D Conversion Method
△Σ
A/D Resolution
≒
1/1,000,000
A/D Conversion Rate
Approx. 120 Times
∕
Sec.
Max. Load Cell Input
Voltage
32mV
ZERO Temperature
Comp.
±
(0.2
μ
V + 0.001% of Dead Load)/
℃
TYP
SPAN Temperature
Comp.
±
0.001%
℃
TYP
Max. Resolution
1/16,000 (
JIF-2002
Resolution can reach
1/60,000 depending on load cell quality &
performance).
3-2 General
◎
General
Type JIF-2002
Power Requirements
AC 110V or AC 220V
±
10%
,
50
∕
60Hz, Approx. 17VA
Net weight
Approx. 3.2 kg
﹝
7.054 lb
﹞
Operation Temperature
-
10
℃∼
45
℃
Maximum Humidity
85%
﹝
non-condensing
﹞
Physical Dimensions
240 (D)
×
190 (W)
×
104(H) mm