Batching Weighing
F000
Set ZERO Range
6 digit Zero band value (
●
Initial ”000.000”)
F101
Batching Mode
●
1
Customer Programmed Control Mode:
Normal Batching
2
Customer Programmed Control Mode:
Loss-in-Weight Batching
3
Built-in Automatic Program Mode: Normal Batching
4
Built-in Automatic Program Mode:
Loss-in weight Batching
F102
Timer-Comparator Inhibitor
Set between 0.0 to 2.0 Sec (
●
Initial 0.0 Sec)
F103
Timer-Finish Signal
The finish signal timer can be Set between 0.0 to 9.9 Sec
※
●
Initial 0.0 Sec
※
Finish Signal sent ON at 0.0 Sec. And stays ON until the next
START Signal