5-2 BATCHING MODES
Batching Modes
1. Customer Programmed Control Mode: Normal Batching
2. Customer Programmed Control Mode: Loss-in-Weight Batching
3. Built-in Automatic Program Mode: Normal Batching
4. Built-in Automatic Program Mode: Loss-in weight Batching
5. Multiple-Ingredient Batching
◎
Customer Programmed Control Mode: Normal Batching
( F101 = 1)
SP1 – Full Flow Gate
SP2 – Medium Flow Gate
Free – Dribble Flow Gate
1. The Weighing Hopper is empty, the display shows "0", and all Gates are
closed. If the display is not at ZERO,
input a TARE
signal (Pin 24) to
re-ZERO the display
.
2. Open the Supply Bin's: Full-Flow Gate, Medium-Flow Gate, and
Dribble-Flow Gate.
3. When the display reaches "
Final - SP 1
", the
SP 1
Output (Pin 12) signal will
come
ON
. Closed the Full-Flow Gate by using the SP 1 Output ON signal.
4. When the display reaches "
Final - SP 2
", the
SP 2
Output (Pin 11) signal will
come
ON
.
Closed the Medium-Flow Gate by using the SP 2 Output ON signal.