Built-in Automatic Program Mode: Normal Batching( F101 = 3 )
SP1 - Full Flow Gate
SP2 - Medium Flow Gate
Free - Dribble Flow Gate
Start signal – Pin22
1. The Weighing Hopper is empty, the display shows "0", and all Gates are
closed. If the display is not at ZERO,
input a TARE
signal (Pin 24) to
re-ZERO the display
.
2. Check if the Weighing Hopper is empty using the ZERO Band Output
(Pin 13).
3. Input the Start signal via the Control I/O Interface connector (Pin 22).
When the Start signal is received, then SP 1, SP 2, and Free Output
signals will "come ON".
Note: When the Final Weight is 0, the Pin 12, 11 and 10 are kept OFF.
4. Open the Supply Bin's: Full-Flow Gate, Medium-Flow Gate, and
Dribble-Flow Gate.
5. When the display reaches "
Final - SP 1
", the
SP 1
Output (Pin 12) signal
will come
OFF
. Closed the Full-Flow Gate by using the SP 1 Output OFF
signal.
6. When the display reaches "
Final - SP 2
", the
SP 2
Output (Pin 11) signal
will come
OFF
.
Closed the Medium-Flow Gate by using the SP 2 Output OFF signal.