8. When the display reaches "
Final - SP 2
", the
SP 2
Output (Pin 11) signal will
come
OFF
. Closed the Full-Flow Gate by using the SP 2 Output OFF signal.
9. When the display reaches "
Final - FREE
", the FREE Output (Pin 10) signal
will come
OFF
. Closed the Dribble-Flow Gate by using the FREE Output
OFF signal.
10. Batch Finish signal is sent after the set time period (F103) or when the
display is stable.
11. After Free Fall has stopped - check if the HI and LO (Pin 9, 8) signals are
OFF. If both outputs are OFF then the batch is completed correctly.
12. Automatic Free Fall is now recalculated for the next event.
13.The Weighing Hopper Discharge Gate will be opened using the Finish
Output (Pin 7) ON signal.
14. Data Output is sent (Auto print Mode: BCD, RS-232C, RS-422/485, Printer
or Current Loop). The NET Weight data will be accumulated.
15. Signal (Pin 13) will refill using ZERO Band Output if needed.
16. Ready for next batching event.
17. If an Abort signal is sent (Pin 21) anytime after the Start signal is received,
then:(1) SP 1, SP 2 and Free signals will go OFF, and Gates will be closed.
(2) Batch Finish and Data Output signals will be sent.
(3) NET Weight data will be accumulated.
Summary of Contents for JIF-2002
Page 1: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 1 CHAPTER 1 INTRODUCTION ...
Page 5: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 5 CHAPTER 2 INSTALLATION ...
Page 9: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 9 CHAPTER 3 SPECIFICATIONS ...
Page 17: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 17 CHAPTER 4 SYSTEMFUNCTIONS ...
Page 41: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 41 CHAPTER 5 SET POINTS ...
Page 54: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 54 CHAPTER 6 OPTIONS ...