JIF-2002 WEIGHING INDICATOR&CONTROLLER
42
5-1 SET POINTS
5-1-1
Change Set point code and Set point values
F106
Input Mode
Set Point Input
1
Panel key
From Panel key
2
BCD Input: Code Input
from rear panel
From Panel key
3
Serial Input: RS-232 or
RS-422/482 when
F203=5
From Panel key or Serial
Input
How to change Set point Code: After press SET POINT/ CODE key,
please press the
↵
key to show the current set-point code.
Use the
or
key to change set point code and the
or
key to change value. Please press the
↵
key to finish changing
set-point code. The relay will work according to the specific
set-point code.
±
Please identify the function F106=1.
Otherwise, the operator can only review the set-point codes.
5-1-2
Change Set point values
How to change Values
within
Set point Codes: Please press
*
key,
then press SET POINT/CODE key. The screen will show blinking
CODE 00.
STEP 1:
Use the or key to change position and the or
key to
change set point code. Please press the
↵
key to finish
changing set-point code.
STEP 2:
The screen will show
Final.
Please press the
↵
key, and the
screen will show 6-digit value with blinking 0 000.000. Use the
or
key to change position
and
or
key to change
value. Please press the
↵
key to confirm FINAL value.
Summary of Contents for JIF-2002
Page 1: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 1 CHAPTER 1 INTRODUCTION ...
Page 5: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 5 CHAPTER 2 INSTALLATION ...
Page 9: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 9 CHAPTER 3 SPECIFICATIONS ...
Page 17: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 17 CHAPTER 4 SYSTEMFUNCTIONS ...
Page 41: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 41 CHAPTER 5 SET POINTS ...
Page 54: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 54 CHAPTER 6 OPTIONS ...