PhaseStation 53100A User’s Manual V1.04 25-Apr-2022
79
Export ASCII xDEV trace
Available in the
Measurement
→
Allan Deviation (
a
),
Measurement
→
Modified Allan
Deviation (
m
), Measurement
→
Hadamard Deviation (
h
),
or
Measurement
→
Time
Deviation (
t
)
views, this command creates an ASCII text file containing a
tau, sigma(tau)
value pair for each visible xDEV bin in the selected plot. One value pair is written per
line; each value is rendered with 16 digits of precision to the right of the decimal point.
The number and distribution of xDEV bins may be specified prior to acquisition with the
Bin Density
field in the
Frequency Stability
tab of the acquisition dialog. Additionally,
the selected plot’s bin density may be adjusted after acquisition through the
Edit
→
Trace properties
dialog. See the help fields in these dialogs for details.
By default, the exported
tau, sigma(tau)
pairs will be saved with the suffix .CSV for ease
of reading into Excel and other spreadsheets.
Export ASCII AM/PM noise trace
Available in the
Measurement
→
Phase noise (
P
)
and
Measurement
→
AM Noise (
A
)
views, this command creates an ASCII text file containing
offset, dBc/Hz
values
corresponding to the visible noise trace for the selected plot. One value pair is written
per line; each value is rendered with 16 digits of precision to the right of the decimal
point.
One
offset, dBc/Hz
pair is written for each pixel column in the displayed graph. This
means that if you zoom in on a portion of the phase noise or AM noise graph, only the
trace data corresponding to the visible area of the selected plot will be exported.
Conversely, if the graticule’s X-axis boundaries extend beyond the minimum or
maximum offset for the selected plot, no
offset, dBc/Hz
pairs outside the valid range will
appear in the exported file.
By default, the exported
offset, dBc/Hz
pairs will be saved with the suffix .CSV for ease
of reading into Excel and other spreadsheets.
Note that when
Show imaginary part of cross spectrum (
Ctrl-F3
)
is active, the
File
→
Export AM/PM noise trace
command will export the imaginary cross spectrum
trace data rather than the normal AM noise or phase noise trace.
Export AM/PM spur table
Available in the
Measurement
→
Phase noise (
P
)
and
Measurement
→
AM Noise (
A
)
views, this command creates an ASCII text file containing
offset, dBc
values
corresponding to entries in the spur table for the selected plot. One value pair is
written per line; each value is rendered with 16 digits of precision to the right of the
decimal point.
See “Spurs” on page 72 for more about spur detection and measurement.
Summary of Contents for PHASE STATION 53100A
Page 1: ...TM 53100A Phase Noise Test Set User s Manual Revision 1 04 April 25 2022...
Page 16: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 16...
Page 18: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 18...
Page 20: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 20...
Page 30: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 30...
Page 36: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 36...
Page 42: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 42...
Page 64: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 64...
Page 74: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 74...
Page 104: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 104...
Page 116: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 116...
Page 122: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 122...
Page 130: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 130...
Page 140: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 140...
Page 214: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 214...
Page 215: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 215 Appendix Legal and regulatory notices...