PhaseStation 53100A User’s Manual V1.04 25-Apr-2022
77
Export ASCII phase data (
x
)
This command is supported only when viewing the selected plot’s phase record
contents using
Measurement
→
Phase difference (
p
)
or
Measurement
→
Frequency-
difference (
f
)
. It will save an ASCII text file containing phase difference data in seconds,
one entry per line, at 16 digits of precision to the right of the decimal point.
If a selected or zoomed area has been defined by dragging with the mouse, only that
portion of the phase record will be exported.
By default, the exported phase data will be saved with the suffix .CSV for ease of reading
into Excel and other spreadsheets. Exported data may be re-imported into TimeLab, if
necessary, by the
File
→
Import ASCII phase or frequency data
command. Select “All
files” as the file type if the data was not exported with the suffixes .TXT or .DAT, then
select
Phase difference (sec)
as the file data type.
Optionally, each sample in the ASCII phase data file can be timestamped with its
absolute MJD or the number of elapsed seconds since the beginning of the phase
record.
Export ASCII frequency data (
X
)
This command is supported only when viewing the selected plot’s phase record
contents using
Measurement
→
Phase difference (
p
)
or
Measurement
→
Frequency-
difference (
f
)
. It will save an ASCII text file containing absolute frequency readings in
hertz, one entry per line, at 16 digits of precision to the right of the decimal point.
If a selected or zoomed area has been defined by dragging with the mouse, only that
portion of the phase record will be exported.
By default, the exported frequency readings will be saved with the suffix .CSV for ease of
reading into Excel and other spreadsheets. Exported data may be re-imported into
TimeLab, if necessary, by the
File
→
Import ASCII phase or frequency data
command.
Select “All files” as the file type if the data was not exported with the suffixes .TXT or
.DAT, then select
Frequency (Hz)
as the file data type.
Optionally, each sample in the ASCII phase data file can be timestamped with its
absolute MJD or the number of elapsed seconds since the beginning of the phase
record.
Summary of Contents for PHASE STATION 53100A
Page 1: ...TM 53100A Phase Noise Test Set User s Manual Revision 1 04 April 25 2022...
Page 16: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 16...
Page 18: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 18...
Page 20: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 20...
Page 30: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 30...
Page 36: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 36...
Page 42: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 42...
Page 64: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 64...
Page 74: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 74...
Page 104: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 104...
Page 116: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 116...
Page 122: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 122...
Page 130: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 130...
Page 140: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 140...
Page 214: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 214...
Page 215: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 215 Appendix Legal and regulatory notices...