ITW Dynatec c. 2003
Appendix B pg. 7
DY2008 Controller Manual #50-14
Revised 2/05
Computer Data Interface Connector (STRSPC)
The Computer Data Interface option (28.00005.107) offers control of the DY2008
Control Unit by an external computer via an RS232 or RS485 communication protocol.
The ribbon cable from the Computer Data Interface Card Option is attached to the
STRSPC connector on the back of the DY2008 front panel.
Output LED Connector
A ribbon cable will be connected from the drive outputs on the back side of the Control
Unit to this connector to power these LEDs. These LEDs are only used in four or eight-
channel versions that do not have a Remote Front Panel Option (28.11101.601). The
drive output LEDs are installed on the main unit front panel blank for all units equipped
with the Remote Front Panel.
Remote Purge Control Board Option (28.11101.602)
The Remote Purge Control (28.11101.602) provides control of the purge function from a
distance up to 10M (33 ft.) from the Operator Interface Unit when used with any version
of the DY2008 Pattern Control. This is normally a factory-installed option consisting of a
PC Board with ribbon cable that is installed inside the DY2008, a hand-held purge
control box and a ten meter (33 ft.) cable to connect the purge control box to the
DY2008. See the chapter on Installation for more details on purge control box
connection.
RS485 Connector and Jumpers
The Remote Purge Option board has two 9-pin “D” connectors mounted on it; one
marked “485” and one marked “232”. The connector marked “485” is the one to be used
with this option. Likewise, there are two jumpers immediately behind the “485”
connector. These should both be jumpered for the indicated “485” setting.
Ribbon Cable Connection
The ribbon cable supplied with the Remote Purge Option is connected to the board on
one end and the STRS458RMC connection on the back of the Control Unit front panel on
the other end. See the previous section about the front panel for details on the location of
this connection point.