8
RETURN
ACCESS CODE:
----
STOP
1:
0 m/min
2:
0 m/min
3:
0 m/min
4:
0 m/min
RETURN
STOP
C
CONTRAST-
RETURN
1:
0 m/min
2:
0 m/min
3:
0 m/min
4:
0 m/min
STOP-CONFIGURATION
PC-COMMUNICATION
RESERVE
SHUTTER TRIGGER SET
RESERVE
DIGITAL CONFIG
RESERVE
LOAD FACTORY SETUP
CHANGE SECURITY LOCK
1
2
3
4
5
6
7
8
9
Code
--
--
--
--
--
--
--
SERVICE SETTINGS
3 OF 3
Manual #50-14 Revised 8/08
Page 4-- 37
C. 1998
Load Factory Default
Factory defaults will be set for parameters in the active
program. This function will not affect the other 59
programs loaded in memory.
Press button 8.
Note!
Always enter Access Code:
This function is protected.
Press the F4 button to exit this menu without
resetting program values to factory defaults.
Press Enter Button after entering Access
Code.
Note!
You cannot recover programmed informa-
tion once the Enter button is pressed.
The following factory defaults will be loaded:
Factory Default Values
Service Settings Menu 1 of 3
No
.
Function
Setting
1
Language
English
2
Program
As per operator selection
3
Trigger Assignment
All Channels are assigned to Trigger 1.
The ’AND’--function is deactivated
4
Trigger Lock
All Channels set to 1 mm (0.01 in)
5
Encoder Assignment
All Channels are assigned to Encoder 1.
6
Encoder Scaling
All Encoders are scaled to 1000 pulses/meter (10.00 ppi)
7
Speed Configuration
All Encoders:
Gluing starts above 20 m/min (20 ft.min)
Gluing stops below 30 m/min (30 ft/min)
Maximum Machine Speed: 600 m/min (600 ft/min)
8
Channel--Mode
All Channels are set to “Standard”
9
Security Lock
Access code 1111, this function locked
All previous functions are unlocked
Summary of Contents for DY 2008