Alarm Outputs (X21)
Two alarm output relays are accessible via
the X21 connector. One of these relays can
be configured for STOP or SYSTEM
READY; the other for ALARM or ZERO
SPEED. Either of the relays can be wired as
“normally open” or “normally closed”. See
page 3-1 (Connectors and Contact Defini-
tions) of this manual for wiring specifica-
tions. Possible settings are described be-
low:
FUNCTION RELAY 1:
STOP:
The relay is triggered each time a
“stop condition” (i.e. STOP, BUS-STOP,
COM-STOP, COM2-STOP or EXTER.
STOP) occurs.
SYSTEM READY:
The relay is triggered each
time a “stop condition” (i.e. STOP, BUS--
STOP,
COM-STOP,
COM2-STOP
or
EXTER. STOP) or zero speed condition oc-
curs.
FUNCTION RELAY 2:
ALARM:
The relay is triggered at the occur-
ance of an internal fault condition, such as
OVER CURRENT or COM-ERROR.
ZERO SPEED:
The relay is triggered each
time a zero speed condition occurs.
Press the Enter Button to save the setting to
memory. Repeat this procedure for each
parameter to be changed.
Press F4 to return to the previous menu.