Manual #50-14 Revised 8/08
Page 4-- 57
C. 1998
Assure the Remote Purge Control is
properly connected to the X31 port on the
back of the DY2008 Control Unit. The
Channel LED indicator at the top of the
Remote
Purge
Control
should
be
illuminated if it is properly connected.
Press the STOP button until the amber LED
in the top, right corner is continuously
illuminated. (Note: a flashing LED indicates
a STOP condition has been activated from
another source, such as the front panel of
the DY2008 Control Unit.
This will not affect the function of the
Remote Purge Control.) COM2-STOP will
be displayed at the top, center of the
DY2008 display (i.e. main control unit) when
the Remote Purge Control activates STOP,
as long as STOP has not also been
activated from any other source (see STOP
FUNCTION in this chapter).
Press the Increment or Decrement button to
select the desired channel for manual
gluing, as indicated in the LED display at the
top of the Purge Control box.
Press the MANUAL GLUING button until
the amber LED at the top, right corner of the
button is illuminated to initiate the manual
gluing function.
NOTE: Manual gluing will be active only
while the button is depressed. It is not pos-
sible to simultaneously activate manual glu-
ing for multiple channels when using the re-
mote purge control.
Press the STOP button until the amber LED
in the top, right corner of the button is OFF
or flashing to exit Manual Gluing.