Manual #50-14 Revised 11/14
Product Description
2 - 3
C. 2002
Valve Mode
Standard Mode
Glue pattern, with or without stitching, is initiated by a trigger
signal. Gluing at speeds between Vmin and Vmax
Standard with Dot-Mode
Glue pattern, with or without stitching, is initiated by a trigger
signal. Gluing at speeds between V-min START and V-min STOP
is Dot Mode. Gluing at speeds above V-min STOP is Standard
Mode.
Dot Mode
Dot- Mode between Vmin and Vmax
Random Product Length
Automatic adjustment of the pattern length to different product
length. Start and Stop of the pattern is controlled with a trigger
signal. Pattern can be stitched or continuous.
Continuous Gluing with Trigger
Continuous gluing controlled with a trigger signal (i.e. glue active
when trigger active). Gluing starts above 1 m/min or 1 ft/min
Continuous with Trigger and Low Speed Cut Off
Continuous gluing controlled with a trigger signal (i.e. glue active
when trigger active).Gluing starts when machine speed between
Vmin and Vmax
Continuous Gluing with Low Speed
Continuous gluing starts at machine speed between Vmin and
Vmax, no trigger input is required
Glue Pattern
Maximum selectable Pattern and Delay Length
0- 8000 mm in steps of 1 mm
0- 80.00 inch in steps of 0.01 inch
Stitching: Glue Bead and Break Length
1- 200 mm in steps of 1 mm
0.01- 2.00 inch in steps of 0.01 inch
Dot Mode
Breaks:
1- 8000 mm in steps of 1 mm
0.01- 9.99 inch in steps of 0.01 inch
Dot Length:
0.10- 9.90 ms
Pressure Control Output
Max. Number
4
Connectors X24 to X27
4- 20 mA or 0- 20 mA and 0- 10 V scalable
Assignment
Each Pressure Control Output can be assigned to any Encoder
Pressure Range
min/max-Limits 0 to 100 %
Pressure Control Mode
2- or 12- Point Curve
Shutter Control
Output Connector X23
24V DC, max. 2 A
Trigger Input X20
Controlled by dedicated input or one of the Master Triggers
Machine contact, Alarm outputs and Interfaces
Machine contact X19
NPN, normally open contact required
Ready- /Alarm output connector X21
Normally open / normally closed, potential- free 24V DC, max. 500
mA or 230V AC, max. 500 mA,
RS232/485 Interface Connector X30
Option
Profibus Connector X28, X29
Option