Page 4-- 10
Manual #50-14 Revised 8/08
C. 1998
Service Settings Menu 2 of 3
No
.
Function
Setting
1
Trigger Setup
All Triggers set to NPN
2
Pressure Signaling
All Pressure outputs set to 4--20 mA
3
Pressure Assignment
All Pressure outputs assigned to Encoder 1
4
Pressure Curve
All Outputs set to 2--Point curve
5
Spike Voltage
All Channels set to 55 V
6
Spike Duration
All Channels set to 1.6 ms
7
Shutter Assignment
The Shutter output (X23) is assigned to the shutter trigger
(X20)
8
Shutter Dwell Time
2 sec.
9
Security Lock
Accesscode 1111, this function locked
All previous functions are unlocked
Service Settings Menu 3 of 3
No
.
Function
Setting
1
STOP--Configuration
All Channels: “NOT FINISH GLUING UPON RESTART”
2
PC--Communication
As previously programmed
3
Reserve
not used, Function locked
4
Shutter Trigger Setting
NPN
5
Reserve
not used, Function locked
6
Digital Configuration
Machine Contact: Normally Open
Relay 1: Stop
Relay 2: Alarm
7
Reserve
not used, Function locked
8
Load Factory Default
Function Locked
9
Security Lock
Access code 1111, this function locked
All previous functions are unlocked
Production Menus
Function
Setting
Pattern
All Channels: Del.1 = 10mm (0.10 in), Glue 1 = 20 mm (0.20 in)
Pressure
All Outputs: Min: 0%, Max: 100%, Purge: 70%
Stitch
All Channels: Glue 4mm (0.04 in), Gap 4mm (0.04 in), no stitch
functions are active
Offset
All Channels: 20mm (0.20 in)
Compensation
All Channels: ON: 0, OFF: 0
Summary of Contents for DY 2008
Page 2: ......
Page 3: ......
Page 4: ......
Page 91: ...ITW Dynatec c 2003 Appendix B pg 9 DY2008 Controller Manual 50 14 Revised 1 09 ...