STOP
C
CONTRAST-
RETURN
1:
0 m/min
2:
0 m/min
3:
0 m/min
4:
0 m/min
STOP-CONFIGURATION
PC-COMMUNICATION
RESERVE
SHUTTER
RESERVE
DIGITAL
RESERVE
LOAD FACTORY SETUP
CHANGE SECURITY LOCK
1
2
3
4
5
6
7
8
9
Code
--
--
--
--
--
--
--
SERVICE SETTINGS
3 OF 3
Manual #50-14 Revised 8/08
Page 4-- 9
C. 1998
Service Settings Menu 3 (of 3) Overview
1 STOP--Configuration:
Use this menu to select
the Stop Mode for each channel: Complete or do
not complete an interrupted gluing pattern upon
machine restart.
2 PC--Communication:
Use this menu to select
RS232 or RS485 data protocol and to adjust the
baud rate.
3 Reserve:
This menu is not used.
4 Shutter Trigger Setup:
Use this menu to select a NPN or PNP shutter trigger
device.
5 Reserve:
This menu is not used.
6 Digital Configuration:
Use this menu to configure the Machine Contact (X19) and
Alarm Output (X21).
7 Reserve:
This menu is not used.
8 Load Factory Setup:
In this menu you can reload the factory default for the active
program. After entering the access code the active program will be reset to the
values listed below.
9 Change Security Lock:
This menu is used to lock individual functions to prevent
unauthorized modification. Additionally it is possible to change the access code. You
can lock/unlock every above mentioned function. After locking, these functions are
only available via access code. Locking/Unlocking is only possible if you know the
access code.
Factory Default Values
Service Settings Menu 1 of 3
No
.
Function
Setting
1
Language
English
2
Program
As per operator selection
3
Trigger Assignment
All Channels are assigned to Trigger 1.
The ’AND’--function is deactivated
4
Trigger Lock
All Channels set to 1 mm (0.01 in)
5
Encoder Assignment
All Channels are assigned to Encoder 1.
6
Encoder Scaling
All Encoders are scaled to 1000 pulses/meter (10.00 ppi)
7
Speed Configuration
All Encoders:
Gluing starts above 20 m/min (20 ft.min)
Gluing stops below 30 m/min (30 ft/min)
Maximum Machine Speed: 600 m/min (600 ft/min)
8
Channel--Mode
All Channels are set to “Standard”
9
Security Lock
Access code 1111, this function locked
All previous functions are unlocked
Summary of Contents for DY 2008
Page 2: ......
Page 3: ......
Page 4: ......
Page 91: ...ITW Dynatec c 2003 Appendix B pg 9 DY2008 Controller Manual 50 14 Revised 1 09 ...