RETURN
MIN. PRESSURE
MAX. PRESSURE
PURGE PRESSURE
PRESSURE SETTINGS OUTPUT 1
10%
90%
80%
1:
0 m/min
2:
0 m/min
3:
0 m/min
4:
0 m/min
OUTPUT
8
OUTPUT
RETURN
0
10%
SPEED
PRESS
1:
0 m/min
2:
0 m/min
3:
0 m/min
4:
0 m/min
PRESSURE SETTINGS OUTPUT 2
110
18%
150
27%
200
36%
250
45%
300
54%
350
63%
SPEED
PRESS
400
72%
450
81%
500
90%
550
99%
600
100%
OUTPUT
PURGE PRESSURE
70%
123
1
Page 4-- 46
Manual #50-14 Revised 8/08
C. 1998
Purge Pressure Adjustment (2-Point Curve)
Press button F1 or F2 until the Purge
Pressure value is highlighted.
Use the numeric keys to enter the pressure
for manual gluing, e.g. 80%.
Select the next pressure output using the F3
button.
Procede with addtional adjustment in the
same way.
Assigning the Pressure Points to the Machine Speed (12-Point Curve)
Assumption for this menu: the selected output has been set to 12-Point Curve in the Service
Setting Menu 2 of 3, Function 4.
The upper lines in this table show the machine speed.
The lower lines show the corresponding output
pressure in percent. It is possible to randomly adjust
the values for machine speed and the associated
pressure in order to create a non-linear pressure vs.
speed curve. Minimum speed is always set to zero,
maximum speed is set to the “MAX SPEED” value
programmed in Service Settings Menu 1 of 3, Function
7.
Use buttons F1 and F2 to select the position
in the table you want to change.
Use the numeric keys to enter a new value.
Repeat the procedure for additional points
in the pressure curve.