RETURN
STOP
C
CONTRAST-
RETURN
1:
0 m/min
2:
0 m/min
3:
0 m/min
4:
0 m/min
STOP-CONFIGURATION
PC-COMMUNICATION
RESERVE
SHUTTER TRIGGER SET
RESERVE
DIGITAL CONFIG
RESERVE
LOAD FACTORY SETUP
CHANGE SECURITY LOCK
1
2
3
4
5
6
7
8
9
Code
--
--
--
--
--
--
--
SERVICE SETTINGS
3 OF 3
RETURN
ACCESS CODE:
----
STOP
1:
0 m/min
123
Manual #50-14 Revised 8/08
Page 4-- 35
C. 1998
Press F4 to return to the previous menu.
Digital Configuration
This menu allows configuration of the Machine Contact
(X19) and the two Alarm Output (X21) relays.
Press button 6.
Enter Access Code if this function is
protected.
Press the Enter Button after entering the Ac-
cess Code.
Use the F1 or F2 Button to select the item to
be changed.
Use the F3 button to highlight the current
value.
Use the F1 or F2 Button to change the para-
meter to the desired value. Value descrip-
tions are as follows:
Machine Contact (X19)
The machine contact provides a means of
disabling the pattern control drive outputs
via a customer-supplied external relay.
EXTER.STOP is displayed at the top, center
of the control unit display when the drive out-
puts have been disabled due to this func-
tion. Possible settings for this menu item are
described below:
N.O. (Normally Open):
Drive outputs are en-
abled when the X19 contacts are open and
disabled when they are closed.
N.C. (Normally Closed):
Drive outputs are dis-
abled when the X19 contacts are open and
enabled when they are closed.
STOP
1:
0 m/min
SHUTTER DWELL TIME MENU
MACHINE CONTACT:
FUNCTION RELAY 1:
FUNCTION REPLAY 2
RETURN
DIGITAL INPUT/OUTPUT MENU
NPN
N.O.
STOP
ALARM
Summary of Contents for DY 2008
Page 2: ......
Page 3: ......
Page 4: ......
Page 91: ...ITW Dynatec c 2003 Appendix B pg 9 DY2008 Controller Manual 50 14 Revised 1 09 ...