Manual #50-14 Revised 8/08
Page 4-- 1
C. 1998
Operation
Operator’s Panel
DY2008
C 1: S
C 2: S
C 3: D
C 4: S
C 5: S
C 7: C
C 8: R
STOP
PATTERN
SYSTEM
COMP.
1: 0 m/min
PRESS1: 0%
PRESS2: 0%
PRESS3: 0%
PRESS4: 0%
PROGRAM:
Machine Speed
All Channels stopped via serial interface
All Channels stopped via Purge Control
All Channels stopped via Profi--Bus
All Channels manually stopped
Stop cause by external contact
EXTER.STOP
STOP
Manual Gluing (Purge)
Service Menu
Manual Stop
Enter Button
Clear Button
Numeric Keys
Function Keys
Glue Pattern:
Channel 1: 3 Glue Events
Channel 2: 1 Glue Event
Channel 3: Dot Mode, 1 Event
Channel 4: 4 Glue Events
Channel 5: 5 Glue Events
Channel 6: Turned Off
Channel 7: Continuous Gluing
Channel 8: Random Length Gluing
Pressure Indication
Program Number
1
2: 0 m/min
3: 0 m/min
EXTER.STOP
Encoder 2
Encoder 1
BUS-STOP
COM 2-STOP
4: 0 m/min
LEDs Signal
Activation of the
Valve Outputs
PRESSURE
S: Trigger Indication for Standard Mode Gluing
C: Trigger Indication for Continuous Mode Gluing
D: Trigger Indicator for Dot Mode Gluing
R: Trigger Indication for Random Mode Gluing
Encoder 3
Encoder 4
COM-STOP
Function Keys F1, F2, F3, F4
These keys can have changing functions. The lower line of the display above
the keys will indicate the current function.
Manual Gluing (Purge) Button
This button is used to activate the valve outputs manually. It is possible to select individual
channels. The button operates only when manual stop (see below) mode is activated.
Service Button
Use this button to open the configuration menu. The button operates only when manual stop (see
below) mode is activated.
Stop Button
Pressing this button will stop gluing. “STOP” will flash at the top, center of the display when this
mode is active.
Numeric Keys
Use these keys to enter parameter values.
Clear Button
Pressing this button will reset a parameter to the previously programmed value or to “0” (zero),
depending upon the specific parameter.
Enter Button
This button is used to confirm a new entry.
Summary of Contents for DY 2008
Page 2: ......
Page 3: ......
Page 4: ......
Page 91: ...ITW Dynatec c 2003 Appendix B pg 9 DY2008 Controller Manual 50 14 Revised 1 09 ...