SCREEN BLINDS
SCREEN LITE
Assembly
Assembly of cords in roller blinds without boxes
Steel cords Ø 4 mm are supplied cut to length with a pre-pressed threaded end piece. The exact cord configuration may
vary per specific projects. After attaching the upper box, pass the cord through the attachment roller on the side board and
secure with a bolt.
Lower brackets can be installed on the side or
front, while the angle section aims down (a) or up
(b).
Note: The places for the installation of the brackets
must be selected before ordering the roller blinds,
as this position determines the cord length.
If brackets are installed upwards (b), leave at least
20 mm of space between the bracket and the
floor or window sill.
Attach the brackets to the wall using screws and
components suitable for the type of structu-
re onto which they are to be attached (metallic
structure, cement, brick, etc.). A gap of 1–2 mm
should be left between the lower section and the
wall/window to prevent mutual damage during
operation. If necessary, increase the bracket di-
stance from the wall by washers. Always tighten the
cord and hold it to prevent twisting.
NOTE
Check parallelism and rectangularity of the four atta-
chment points. This can be done by measuring two
distances “S1” and “S2” or diagonals “D1” and “D2”.
The dimensions must be the same ±1 mm.