INSTRUCTIONS FOR USE OF THE ELECTRONIC THERMOSTAT  

(Fig. C) 

The electronic control consists of a thermostat that allows you to choose the ambient temperature from 7°C to 35°C. 
 

INSTRUCTIONS FOR USE AND OPERATION 

1.  PRESENTATION 

The electronic thermostat has 4 buttons and 1 display (Figure 1). The electronic thermostat is started by pressing the [ON/Standby] button: when the 
electronic thermostat is in standby, the flashing letters “St by” appear on the display; when it is in the chrono modes, the program appears with the 
indication of the time or the number of the selected integrated program (P1, P2, P3), or the setting of the mode temperature. 
 
 
 
 
 
 
 
 
 
 
 

2.  STAND-BY OPERATION 

When changing from STAND-BY to one of the operating modes, the electronic thermostat emits a sound lasting 1 second. 
Vice-versa, when changing from one of the operating modes to STAND-BY, the electronic thermostat 
emits two short sounds with a pause of half a second between them. 
When it is powered, the electronic thermostat emits a warning sound to indicate its status according to the 
logic described above. 
 
Next to the display is a coloured bar: an arrow on the display indicates one of the three colours depending 
on the current temperature setting, as in the table below. This indicator provides a visual indication that 
setting high temperatures results in a higher energy consumption. 
 

3.  DESCRIPTION OF USE 

The electronic thermostat has 8 operating modes: 1 pre-set free chrono program, 3 integrated chrono programs, pilot-wire, comfort, night and 
antifreeze. To change from one mode to another, press the FUNCTIONS button 
 

Table 2: Operating modes 

Operating mode 

Icon 

Operating mode description 

CHRONO 

 

Follows the weekly programming on two temperature levels (high and low) defined by the user hour by hour. 
All the PILOT-WIRE controls are disabled except STOP. 

P1 FIXED 

PROGRAM 

 

P1 fixed weekly program (working week program) on two temperature levels (high and low) pre-defined time hour by 
hour. 
All the PILOT-WIRE controls are disabled except STOP. 

P2 FIXED 

PROGRAM 

 

P2 fixed weekly program (working week program) on two temperature levels (high and low) pre-defined time hour by 
hour. 
All the PILOT-WIRE controls are disabled except STOP. 

P3 FIXED 

PROGRAM 

 

P3 fixed weekly program (working week program) on two temperature levels (high and low) pre-defined time hour by 
hour. 
All the PILOT-WIRE controls are disabled except STOP. 

PILOT-WIRE

 

 

The locally set high temperature is modified according to the controls received from the Pilot-Wire unit, except in the 
case where the Pilot-Wire is not connected, or with class 1 regulators (products with an earth connection). 
The ELECTRONIC THERMOSTAT recognises 6 controls: comfort, reduction (high temperature -3.5°C), stop, 
antifreeze (7°C), eco1 (high temperature -1°C) and eco2 (high temperature -2°C) 

COMFORT 

 

Regulation without time limits on the high temperature level. 
All the PILOT-WIRE controls are disabled except STOP. 

NIGHT

 

 

Regulation without time limits on the low temperature level. 
All the PILOT-WIRE controls are disabled except STOP. 

ANTIFREEZE

 

 

Regulation without time limits on 7°C. 
All the PILOT-WIRE controls are disabled except STOP. 

 
Two different temperature levels can be set, high and low. High temperature is used in the chrono modes, P1, P2, P3, Pilot-Wire and comfort. Low 
temperature is used in the chrono modes, P1, P2, P3 and night. High temperature can be modified in comfort mode while low temperature can be 
modified in night mode using the [+] and [-] keys. The flashing thermometer symbol indicates that modification is in progress. During modification, the 
high temperature can be decreased to the current low temperature value and, vice-versa, the low temperature can be increased to the current high 
temperature value.

 

 
IMPORTANT: changes in the ambient temperature are normal when using electronic thermostats when there are variations in the power requested or 
when the environmental conditions change outside the room that is to be heated. The set value is correct only for radiators installed in standard 
environments. It is normal for the regulator setting to be different to obtain the same temperature in different environments (influence of the 
surrounding environment).

 

 
In chrono mode the temperature levels are used as illustrated in figure 3. 
 
 
 
 
 
 

Thermometer symbol 

Operating mode icon 

Behaviour indicator 

Fig. Display Focus 

Figure 3: Chrono mode temperature levels 

High temperature 

Low temperature 

Table 1: Indication of consumption

 

Colour

 

Temperature setting

 

Red 

>24 °C 

Yellow 

>19 °C and 

24 °C 

Green 

19 °C 

 

Fig.1 

Display 

Functions 

button 

 

Button  

 

Button  

 

ON/Standby 

button 

 

Summary of Contents for RT306000801IRF0N

Page 1: ...iali e mentali o prive di esperienza o conoscenze adatte non devono eseguire operazioni di pulizia o manutenzione ordinaria al radiatore E assolutamente vietato Dare alimentazione al controllo della r...

Page 2: ...one dello STOP PROGRAMMA FISSO P3 Programma settimanale fisso P3 programma settimana di lavoro su due livelli di temperatura alta e bassa predefiniti ora per ora Tutti i comandi FIL PILOTE sono disabi...

Page 3: ...settimanale effettuata il modo corrente compreso il blocco tastiera e le impostazioni di temperatura alta e bassa mentre necessario reimpostare l orario Al successivo ritorno dell alimentazione elettr...

Page 4: ...zioni e per qualche secondo fino a quando non compare la scritta Foff sul display dopo di che si ritorna alla schermata precedente figura 13 NOTA 1 Se il termostato elettronico sembra funzionare regol...

Page 5: ...Les enfants et les personnes avec des capacit s physiques sensorielles et mentales r duites ou sans exp rience ou connaissances appropri es ne doivent pas effectuer des op rations de nettoyage ou de...

Page 6: ...TOP PROGRAMME FIXE P3 Programme hebdomadaire fixe P3 programme hebdomadaire de travail sur deux niveaux de temp rature lev e et basse d finis heure par heure Toutes les commandes FIL PILOTE sont d sac...

Page 7: ...ste la programmation hebdomadaire effectu e le mode courant y compris le blocage du clavier et les param trages de temp rature lev e et basse alors que l horaire doit tre reprogramm Lorsque l alimenta...

Page 8: ...affichage de la lettre F off sur l cran on retourne ensuite la page cran pr c dente figure 13 REMARQUE 1 Si le thermostat semble fonctionner r guli rement et que le radiateur ne chauffe pas cette sit...

Page 9: ...entales reducidas o que carezcan de experiencia o de los conocimientos adecuados no deben realizar operaciones de limpieza o mantenimiento ordinario del radiador toallero Est terminantemente prohibido...

Page 10: ...ilitados con excepci n del STOP PARO PROGRAMA FIJO P3 Programa semanal fijo P3 programa semana de trabajo en dos niveles de temperatura alta y baja predefinidos hora por hora Todos los mandos HILO PIL...

Page 11: ...amaci n semanal realizada el modo actual incluido el bloqueo teclado y las configuraciones de temperatura alta y baja mientras que es necesario reconfigurar la hora Si al restablecerse la alimentaci n...

Page 12: ...ir la funci n presionar los botones Funciones y por algunos segundos hasta que en la pantalla aparezca la indicaci n F off despu s de lo cual se vuelve a la captura de pantalla anterior figura 13 NOTA...

Page 13: ...ecessary knowledge must not perform cleaning or routine maintenance of the radiator It is absolutely prohibited To power the heating element control before having checked the correct installation of t...

Page 14: ...cept STOP P3 FIXED PROGRAM P3 fixed weekly program working week program on two temperature levels high and low pre defined time hour by hour All the PILOT WIRE controls are disabled except STOP PILOT...

Page 15: ...the memory along with the current mode including keyboard lock and the high and low temperature settings while the time must be reset When the 230V ac power returns if one of the chrono modes is sele...

Page 16: ...a few seconds until the message F off appears on the display after which the system returns to the previous screen figure 13 NOTE 1 If the electronic thermostat seems to be working correctly and the r...

Page 17: ...cesare nu trebuie s efectueze opera ii de cur are sau ntre inere curent a caloriferul Sunt strict interzise Alimentarea dispozitivului de control al rezisten ei de nc lzire nainte de a fi verificat c...

Page 18: ...excep ia comenzii STOP PROGRAM FIX P3 Program s pt m nal fix P3 program s pt m nal de lucru pe dou niveluri de temperatur nalt i joas presetate pentru fiecare or Toate comenzile FIL PILOTE sunt dezac...

Page 19: ...lusiv blocarea tastelor i set rile temperaturilor nalt i joas n timp ce trebuie setat din nou programul orar La restabilirea aliment rii electrice cu 230V ac dac selecta i unul din modurile crono prog...

Page 20: ...va secunde p n c nd pe display apare inscrip ia F off sul display dup care se va reveni la ecranul anterior figura 13 NOTA 1 Dac termostatul electronic pare s func ioneze corect dar caloriferul nu nc...

Page 21: ...ellen oder reinigen Kinder und Personen mit k rperlichen sensorischen und mentalen Einschr nkungen oder ohne einschl gige Erfahrung oder Kenntnisse d rfen am Handtuchtrockner weder Reinigungs noch War...

Page 22: ...L PILOTE Steuerungen sind deaktiviert au er STOPP FESTES PROGRAMM P3 Festes Wochenprogramm P3 Programm der Werktage der Woche auf zwei Temperaturstufen hohe und niedrige die Stunde f r Stunde eingeste...

Page 23: ...mversorgung bleiben die w chentliche Programmierung der aktuelle Modus einschlie lich Tastensperre sowie die Einstellungen f r die hohe und niedrige Temperatur gespeichert w hrend die Uhrzeit neu eing...

Page 24: ...eginnt Um diese Funktion zu deaktivieren die Tasten Funktionen und gleichzeitig solange gedr ckt halten bis am Display die Schrift F off erscheint Danach wird wieder das vorhergehende Fenster angezeig...

Page 25: ...do wiadczenia oraz wiedzy nie mog wykonywa adnych czynno ci czyszczenia ani rutynowej konserwacji grzejnika Obowi zuje ca kowity zakaz pod czania zasilania do kontroli grza ki elektrycznej przed spraw...

Page 26: ...kiem STOP PROGRAM STA Y P3 Program tygodniowy sta y P3 tygodniowy program pracy na dw ch poziomach temperatury wysoka i niska okre lonych godzina po godzinie Wszystkie sterowania FIL PILOTE s wy czone...

Page 27: ...enia wysokiej i niskiej temperatury podczas gdy konieczne jest ponowne ustawienie godziny Po przywr ceniu napi cia elektrycznego 230V ac je eli zostanie wybrany jeden z tryb w crono swobodne programow...

Page 28: ...displayu nast pnie powraca si na poprzedni stron rysunek 13 UWAGA 1 Je eli elektroniczny termostat wydaje si funkcjonowa regularnie a grzejnik nie grzeje w takiej sytuacji oznacza to prawdopodobnie i...

Reviews: