Installation Instructions

Reference

J287c

Complete with 

 

 

REMOTE SWITCH UNIT

for Fan only, 3, 2 and 1kW

RDH 3000

Recessed Over Door 

Heater

Please retain for future reference

Commercial Electric Heat Limited

Burnfoot Industrial Estate 

HAWICK

Roxburghshire

TD9 8SL

Tel 01450 372103 Fax 01450 377800

Email [email protected] Web www.cehltd.co.uk

Summary of Contents for RDH 3000

Page 1: ...H UNIT for Fan only 3 2 and 1kW RDH 3000 Recessed Over Door Heater Please retain for future reference Commercial Electric Heat Limited Burnfoot Industrial Estate HAWICK Roxburghshire TD9 8SL Tel 01450 372103 Fax 01450 377800 Email sales cehltd co uk Web www cehltd co uk ...

Page 2: ...ip bush and locknut ELECTRICAL CONNECTION The heater should be installed in accordance with the latest edition of the IEE Requirements for Electrical Installation BS 7671 2001 The unit should be permanently connected to a suitable 230Vac power supply incorporating a means of isolation having a contact separation of at least 3mm in all poles remote switch unit in suitable location Select cabling wi...

Page 3: ...ter weight Two 8mm holes are provided in the top of the heater to allow the fixing of drop rods by others Fitting in modular ceiling Drop rod fixing This unit is designed for installation in a plasterboard or similar ceiling where a free height above the surface of the ceiling is at least 230mm It is also sized to fit within A 580mm x 130mm hole should be made in the ceiling and suitably framed Fi...

Page 4: ...ement Fan motor Connector block 4 C002 Blower unit 2kW 1kW L LI L LII 2kW 1kW N N 5 ODH RSW Remote Switch Unit Add external cut outs 11 04 6 O T cut out IMPORTANT Any modification to the switching in this circuit must ensure that the heating elements cannot be energised without the fan running Remote Switch ODH RSW 1 Heating element incorporates over temperature cut out To reset Switch off and all...