Goodrive350-UL Series VFD
Product overview
-9-
R
S
T
U
V
W
P1
PE
PE
DC reactor
(+)
(-)
Fig 3.3 Simplified main circuit diagram (VFDs of 575V)
Note:
1. The VFDs of 220V (18.5–55kW) and 460V (≥37kW,) supports external DC reactors and external
braking units, but it is necessary to remove the copper tag between P1 and (+) before connecting.
DC reactors and external braking units are optional.
2. The VFDs of 220V (≤15kW), 460V (≤30kW,) supports external braking resistors which are
optional.
3. The VFDs of 575V supports external DC reactors and external braking units, but it is necessary to
remove the copper tag between P1 and (+) before connecting. DC reactors and external braking
units are optional.
3.3 Product specification
Function description
Specification
Power input
Input voltage (V)
AC 3PH 200V–240V Rated voltage: 220V
AC 3PH 380V–480V Rated voltage: 460V
AC 3PH 520V–600V Rated voltage: 575V
Allowable voltage
fluctuation
-15%–+10%
Input current (A)
See Section 3.6 "Rated specifications".
Input frequency (Hz)
50Hz or 60Hz, allowable range: 47–63Hz
Power
output
Output voltage (V)
0–input voltage
Output current (A)
See Section 3.6 "Rated specifications".
Output power (kW)
See Section 3.6 "Rated specifications".
Output frequency (Hz) 0–400Hz
Technical
control
performance
Control mode
SVPWM control, SVC, VC
Motor type
Asynchronous motor, permanent-magnet synchronous
motor
Speed regulation ratio
Asynchronous motor 1: 200 (SVC); Synchronous motor 1:
20 (SVC) , 1:1000 (VC)