2
2-26
Intrepid® 6140 Director Installation and Service Manual
Installation Tasks
•
Flexport Technology -
A Flexport Technology product is
delivered at a discount without all Fibre Channel ports enabled.
When additional port capacity is required, the remaining ports
are incrementally enabled through this feature.
•
Full volatility -
This feature ensures no Fibre Channel frames are
stored after the director is powered off or fails, and a memory
dump file (that possibly includes classified data frames) is not
included as part of the data collection procedure.
•
N_Port ID virtualization -
This feature allows up to 256 Fibre
Channel addresses to be assigned to an N_Port.
•
Open systems management server -
These feature supports
inband director management through OSMS host control.
•
OpenTrunking -
This feature provides dynamic load balancing of
Fibre Channel traffic across multiple ISLs.
•
Preferred path -
This feature allows a user to configure a path
between multiple fabric elements (directors or fabric switches) by
configuring the source and exit ports of the origination fabric
element and the Domain_ID of the destination fabric element.
•
SANtegrity authentication -
This feature enhances security in
SANs by restricting access to Fibre Channel elements (directors or
fabric switches).
•
SANtegrity binding -
This feature enhances security in SANs
with a large and mixed group of fabrics and attached devices.
After purchasing a feature, obtain the PFE key by following the
enclosed instructions. The key is an alphanumeric string consisting of
uppercase and lowercase characters that must be entered exactly,
including dashes. An example format is:
XxXx-XXxX-xxXX-xX.
Keys are encoded to work only with the serial number of the installed
director. Record the key to re-install the feature if required. If the
director fails and is replaced, obtain new PFE keys from the solution
center (800-752-4572 or [email protected]). Have the serial
numbers of the failed and replacement directors, and the old PFE key
number or transaction code. After obtaining a PFE key, install the
feature as follows:
1. Select Upgrade Options from the Configure, Maintenance, or Security
menus at any view. The Maintenance Feature Installation View
displays (
Figure 2-14
).
Summary of Contents for Intrepid 6140 Director
Page 4: ...Intrepid 6140 Director Installation and Service Manual iv ...
Page 14: ...xiv Intrepid 6140 Director Installation and Service Manual Figures ...
Page 42: ...1 1 20 Intrepid 6140 Director Installation and Service Manual General Information ...
Page 120: ...2 2 78 Intrepid 6140 Director Installation and Service Manual Installation Tasks ...
Page 294: ...6 6 12 Intrepid 6140 Director Installation and Service Manual Illustrated Parts Breakdown ...
Page 366: ...A A 72 Intrepid 6140 Director Installation and Service Manual Event Code Tables ...
Page 370: ...B B 4 Intrepid 6140 Director Installation and Service Manual Director Specifications ...
Page 382: ...D D 8 Intrepid 6140 Director Installation and Service Manual Restore Management Server ...
Page 385: ...E E 3 Safety Notices Multi Lingual Translations ...