A
CTP Card Events (400 through 499)
A-47
Event Code Tables
Event Code: 442
Message:
Embedded port anomaly detected.
Severity:
Informational.
Explanation:
The CTP card detected a deviation in the normal operating mode or status of the embedded port.
Action:
No action required. Additional event code is generated if incident exceeds error threshold or causes a port failure.
Event Data:
Byte 0 = port number.
Byte 12 = detecting port.
Byte 1 = engineering reason code.
Byte 13 = connected port.
Bytes 4 - 7 = elapsed millisecond tick count.
Byte 14 = participating SBAR.
Bytes 8 and 9 = high-availability error callout #1.
Bytes 16 and 17 = high-availability error callout #3.
Bytes 10 and 11 = high-availability error callout #2.
Bytes 18 and 19 = high-availability error callout #4.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Event Code: 450
Message:
Serial number mismatch detected.
Severity:
Informational.
Explanation:
This event occurs when the sequence number or OEM serial number in the system VPD (read from the
backplane) does not match the sequence number and serial number that was saved in NVRAM the last time the
director was IPLed. This event will occur normally when a CTP is moved from one switch to the master position of
another switch. This event may occur abnormally when a hardware problem causes a problem reading the
system VPD from the backplane.
Action:
None. Any configured feature keys will be cleared. Configuration information will be synched with the backplane
VPD, and the CTP will automatically be IPLed.
Event Data:
Bytes 0 - 12 = sequence number from the system VPD.
Bytes 13 - 31 = OEM serial number from the system VPD.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Summary of Contents for Intrepid 6140 Director
Page 4: ...Intrepid 6140 Director Installation and Service Manual iv ...
Page 14: ...xiv Intrepid 6140 Director Installation and Service Manual Figures ...
Page 42: ...1 1 20 Intrepid 6140 Director Installation and Service Manual General Information ...
Page 120: ...2 2 78 Intrepid 6140 Director Installation and Service Manual Installation Tasks ...
Page 294: ...6 6 12 Intrepid 6140 Director Installation and Service Manual Illustrated Parts Breakdown ...
Page 366: ...A A 72 Intrepid 6140 Director Installation and Service Manual Event Code Tables ...
Page 370: ...B B 4 Intrepid 6140 Director Installation and Service Manual Director Specifications ...
Page 382: ...D D 8 Intrepid 6140 Director Installation and Service Manual Restore Management Server ...
Page 385: ...E E 3 Safety Notices Multi Lingual Translations ...