A
A-64
Intrepid® 6140 Director Installation and Service Manual
Event Code Tables
Event Code: 607
Message:
Director contains no operational SBARs.
Severity:
Severe.
Explanation:
The director firmware does not recognize an installed SBAR.
Action:
Install at least one functional SBAR and power-on reset (POR) the director.
Event Data:
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Event Code: 608
Message:
User initiated SBAR switch-over.
Severity:
Informational.
Explanation:
The backup SBAR has become the active SBAR at a user’s request. The previously active SBAR is now the
backup SBAR.
Action:
No action required.
Event Data:
There is no supplementary data included with this event.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Summary of Contents for Intrepid 6140 Director
Page 4: ...Intrepid 6140 Director Installation and Service Manual iv ...
Page 14: ...xiv Intrepid 6140 Director Installation and Service Manual Figures ...
Page 42: ...1 1 20 Intrepid 6140 Director Installation and Service Manual General Information ...
Page 120: ...2 2 78 Intrepid 6140 Director Installation and Service Manual Installation Tasks ...
Page 294: ...6 6 12 Intrepid 6140 Director Installation and Service Manual Illustrated Parts Breakdown ...
Page 366: ...A A 72 Intrepid 6140 Director Installation and Service Manual Event Code Tables ...
Page 370: ...B B 4 Intrepid 6140 Director Installation and Service Manual Director Specifications ...
Page 382: ...D D 8 Intrepid 6140 Director Installation and Service Manual Restore Management Server ...
Page 385: ...E E 3 Safety Notices Multi Lingual Translations ...