![intrepid Intrepid 6140 Director Installation And Service Manual Download Page 112](http://html.mh-extra.com/html/intrepid/intrepid-6140-director/intrepid-6140-director_installation-and-service-manual_2081876112.webp)
2
2-70
Intrepid® 6140 Director Installation and Service Manual
Installation Tasks
•
Preferred path -
Use the Preferred Path option from the Configure
menu (Element Manager application) to specify and configure
one or more ISL data paths between multiple fabric elements. At
each fabric element, a preferred path consists of a source port, exit
port, and destination Domain_ID.
•
Port fencing -
Use the Port Fencing option from the Configure
menu (SAN management application) to minimize ISLs that
bounce (repeatedly attempt to establish a connection), causing
disruptive fabric rebuilds. Fencing defines a bounce threshold
that when reached, automatically blocks the disruptive E_Port.
To configure optional features, refer to the SANavigator Software
Release 4.2 User Manual (621-000013) or EFC Manager Software Release
8.7 User Manual (620-000170) for instructions. If no additional options
or features are to be configured, go to
Task 20: Back Up Configuration
Data
following.
Task 20: Back Up Configuration Data
For the Sanavigator application, critical configuration data is stored
on the management server hard drive in the following directories:
•
C:\Program Files\SANavigator 4.2\CallHome
•
C:\Program Files\SANavigator 4.2\Client
•
C:\Program Files\SANavigator 4.2\Server
.
For the EFCM application, critical configuration data is stored on the
management server hard drive in the following directories:
•
C:\Program Files\EFCM 8.7\CallHome
•
C:\Program Files\EFCM 8.7\Client
•
C:\Program Files\EFCM 8.7\Server
.
The server is configured to automatically mirror the contents of these
directories to the CD-RW drive anytime directory contents change or
the server is rebooted. The directories contain all SAN management
configuration data, log files, firmware versions, call-home and other
configuration data; and are used to restore the server operating
environment in case of hard drive failure.
The server does not back up Windows operating system data, such as
user names, passwords, date and time, and network information.
This information was recorded while performing installation tasks,
Summary of Contents for Intrepid 6140 Director
Page 4: ...Intrepid 6140 Director Installation and Service Manual iv ...
Page 14: ...xiv Intrepid 6140 Director Installation and Service Manual Figures ...
Page 42: ...1 1 20 Intrepid 6140 Director Installation and Service Manual General Information ...
Page 120: ...2 2 78 Intrepid 6140 Director Installation and Service Manual Installation Tasks ...
Page 294: ...6 6 12 Intrepid 6140 Director Installation and Service Manual Illustrated Parts Breakdown ...
Page 366: ...A A 72 Intrepid 6140 Director Installation and Service Manual Event Code Tables ...
Page 370: ...B B 4 Intrepid 6140 Director Installation and Service Manual Director Specifications ...
Page 382: ...D D 8 Intrepid 6140 Director Installation and Service Manual Restore Management Server ...
Page 385: ...E E 3 Safety Notices Multi Lingual Translations ...