5
RRP: CTP Card
5-9
Removal and Replacement Procedures (RRPs)
c. Verify the card stiffener is flush with the front of the card cage
and even with other director logic cards.
5. After the replacement CTP card is installed, note the following:
— When a CTP card with a different firmware version is installed
in a director with an active CTP card, a synchronization
process occurs. This process causes firmware from the active
CTP card to be downloaded to the replacement CTP card. The
process does not occur if both CTP cards have the same
firmware version.
— The synchronization process may take up to ten minutes
(depending on director activity).
ATTENTION!
Allow the synchronization process to complete. If the process
is interrupted by a director power cycle or initial program load (IPL), or by
removing the replacement CTP card, the card may be unusable due to
partially-loaded firmware.
— If after ten minutes the replacement CTP card does not appear
to be operational, perform the data collection procedure and
return the failed replacement card to McDATA (
Collecting
Maintenance Data
on page 4-32).
— Do not reinstall the failed replacement CTP card because this
can corrupt director firmware. Obtain a new CTP card and
perform this replacement procedure.
6. Verify that synchronization is complete by viewing the Event log.
7. Connect the Ethernet LAN cable to the RJ-45 connector on the
faceplate of the replacement CTP card.
8. Disconnect the ESD wrist strap from the director chassis and your
wrist.
9. Inspect the CTP card to ensure the amber LED is extinguished. If
the amber LED is illuminated, go to
Chapter 3
,
Maintenance
Analysis Procedures (MAPS)
to isolate the problem.
10. At the management server or at a web browser connected to the
EFCM Basic Edition interface, inspect the Event Log. Ensure the
following event codes appear in the log:
— 410 - CTP card reset.
— 416 - Backup CTP installed.
Summary of Contents for Intrepid 6140 Director
Page 4: ...Intrepid 6140 Director Installation and Service Manual iv ...
Page 14: ...xiv Intrepid 6140 Director Installation and Service Manual Figures ...
Page 42: ...1 1 20 Intrepid 6140 Director Installation and Service Manual General Information ...
Page 120: ...2 2 78 Intrepid 6140 Director Installation and Service Manual Installation Tasks ...
Page 294: ...6 6 12 Intrepid 6140 Director Installation and Service Manual Illustrated Parts Breakdown ...
Page 366: ...A A 72 Intrepid 6140 Director Installation and Service Manual Event Code Tables ...
Page 370: ...B B 4 Intrepid 6140 Director Installation and Service Manual Director Specifications ...
Page 382: ...D D 8 Intrepid 6140 Director Installation and Service Manual Restore Management Server ...
Page 385: ...E E 3 Safety Notices Multi Lingual Translations ...