A
A-66
Intrepid® 6140 Director Installation and Service Manual
Event Code Tables
Event Code: 621
Message:
Failed SBAR fan recovered.
Severity:
Informational.
Explanation:
System software has detected that one or more failed SBAR fan modules has recovered.
Action:
None.
Event Data:
Bytes 0 - 3 = reserved.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 and 9 = failed SBAR fan count.
Bytes 10 and 11 = operational SBAR fan count.
Byte 12 - 15 = reserved.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident