![Interlogix TruVision TVP-5201 Configuration Manual Download Page 48](http://html1.mh-extra.com/html/interlogix/truvision-tvp-5201/truvision-tvp-5201_configuration-manual_2077171048.webp)
8. Click the
Actions
tab to specify the linkage method for when an event occurs.
Select one or more response methods for the system when an alarm is triggered.
See “Linkage methods” on page 37 for details.
9. Click
Save
to save changes.
Intrusion detection
An area in the surveillance scene can be configured to detect when intrusion occurs. If
someone enters the area, a set of alarm actions can be triggered.
To define intrusion detection:
1. From the menu toolbar, click
Configuration
>
Event
>
Smart Event
>
Intrusion
Detection
.
2. Select the
Enable
check box to enable intrusion detection.
3. Select the region number to be configured from the
Region
drop-down list.
4. Click
Draw Area
, and then draw a rectangle on the image as the defense region.
When drawing the rectangle, connect all lines end-to-end to each other. Up to four
areas are supported. Click
Clear
to clear the areas drawn. The defense region
parameters can be set up separately.
Note
: The drawn area can only be quadrilateral.
5. Set the sliders as follows:
Threshold:
This is the time threshold that the object remains in the region. If the
value is set as 0, the alarm is triggered immediately after the object enters the
region. The range is between 0 and 100.
Sensitivity:
The sensitivity value defines the size of the object that can trigger the
alarm. When the sensitivity is high, a small object can trigger the alarm. The range
is between 1 and 100.
46
TruVision Stainless Steel PTZ Camera Configuration Manual