Error Reporting and Handling
Intel® Server Boards SE7320SP2 and SE7525GP2
Revision
4.0
132
6.2.2
Boot Block Error Beep Codes
Table 61. Boot Block Error Beep Codes
Number of Beeps
Description
1
Insert diskette in floppy drive A:
2
‘AMIBOOT.ROM’ file not found in root directory of diskette in A:
3
Base memory error
4
Flash programming successful
5
Floppy read error
6
Keyboard controller BAT command failed
7
No flash EPROM detected
8
Floppy controller failure
9
Boot block BIOS checksum error
10
Flash erase error
11
Flash program error
12
‘AMIBOOT.ROM’ file size error
13
BIOS ROM image mismatch (file layout does not match image present in flash device)
1 long beep
Insert diskette with AMIBOOT.001 file for multi-disk recovery
6.2.3
POST Error Beep Codes
The following table lists the POST error beep codes. Before system video initialization, the BIOS
uses these beep codes to inform users of error conditions.
Table 62. POST Error Beep Codes
Number of Beeps
Description
1
Memory refresh timer error
2
Parity error in base memory (first 64 KB block)
3
Base memory read / write test error
4
Server board timer not operational
5 Processor
error
6
8042 Gate A20 test error (cannot switch to protected mode)
7
General exception error (processor exception error)
8
Display memory error (system video adapter)
9
ROM checksum error
10
CMOS shutdown register read/write error
11
Cache memory test failed
6.2.3.1
Troubleshooting BIOS Beep Codes
Table 63. Troubleshooting BIOS Beep Codes
Summary of Contents for SE7320SP2 - 800MHZ Ecc Ddr Xeon