General Specifications
Intel® Server Boards SE7320SP2 and SE7525GP2
Revision
4.0
166
8.4.2 Voltage
Recovery
Timing Specifications
The power supply must conform to the following specifications for voltage recovery timing under
load changes:
Voltage shall remain /- 5% of the nominal set voltage on the +5 V, +12 V, 3.3 V, -
5 V and -12 V output, during instantaneous changes in load shown in the following table.
Voltage regulation limits shall be maintained over the entire AC input range and any
steady state temperature and operating conditions specified.
Voltages shall be stable as determined by bode plot and transient response. The
combined error of peak overshoot, set point, regulation, and undershoot voltage shall be
less than or equal to +/-5% of the output voltage setting. The transient response
measurements shall be made with a load changing repetition rate of 50 Hz to 5 kHz. The
load slew rate shall not be greater than 0.2 A/
s.
Table 105. Transient Load Requirements
Output
Step Load Size
Load Slew Rate
Capacity Load
+3.3 V
7.0 A
0.25 A/
s 4700
F
+5 V
7.0 A
0.25 A/
s 1000
F
+12 V
6.25 A
0.25 A/
s 675
F
+5 VSB
500 mA
0.25 A/
s 20
F
Summary of Contents for SE7320SP2 - 800MHZ Ecc Ddr Xeon