background image

 

hp AlphaServer ES47/ES80/GS1280 

I/O Drawer Upgrade 

Order Number:  EK-EGIOD-UP. B01 

This manual is for field service engineers and self-maintenance customers 
who are installing an I/O drawer upgrade into an

 

hp AlphaServer ES47, 

ES80, or GS1280 system.  

Hewlett-Packard Company 

 

 

Summary of Contents for AlphaServer ES47

Page 1: ... O Drawer Upgrade Order Number EK EGIOD UP B01 This manual is for field service engineers and self maintenance customers who are installing an I O drawer upgrade into an hp AlphaServer ES47 ES80 or GS1280 system Hewlett Packard Company ...

Page 2: ...type tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC rules which are designed to provide reasonable protection against such radio frequency interference Operation of this equipment in a residential area may cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interfe...

Page 3: ...lent international standards EN55022 CISPR 22 Electromagnetic Interference EN50082 1 IEC801 2 IEC801 3 IEC801 4 Electromagnetic Immunity EN60950 IEC950 Product Safety Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Gerät der Funkstörgrenzwertklasse A In Wohn...

Page 4: ......

Page 5: ... the I O Drawer 3 1 Install the Inner Slides 3 2 3 2 Determine Hole Locations for Installation 3 4 3 3 Loosely Attach Outer Slides 3 6 3 4 Attach Cable Retainer and Grommet 3 8 3 5 Install the I O Drawer 3 10 3 6 Install Cable Support Rack and Drawer Latches 3 12 3 7 Attach Cable Guides 3 14 3 8 Attach Cable Support Bracket on Rear Door 3 16 3 9 Identify I O Connector on CPU Drawer 3 18 3 10 Conne...

Page 6: ... 5 5 3 Running Q VET 5 6 5 3 1 Tru6h4 UNIX 5 6 5 3 2 OpenVMS 5 6 5 4 Reviewing Q VET Results 5 8 5 5 De Installing Q Vet 5 9 5 5 1 Tru64 UNIX 5 9 5 5 2 OpenVMS 5 9 5 5 3 Q Vet Resources 5 9 Table of Examples Example 4 1 Power Up Display 4 2 Example 4 2 Run Show Cable 4 4 Example 4 3 Run Connect 4 6 Table of Figures Figure 1 1 Example hp AlphaServer System ES80 Model 8 1 2 Figure 2 1 Turn Off Power...

Page 7: ...16 Ethernet Ground and Power Cables 3 26 Figure 3 17 PDU Connections 3 27 Figure 3 18 Replacing the Side Panel Example 3 28 Figure 3 19 Setting Drawer ID 3 30 Figure 3 20 ID Numbers Example for ES80 System 3 31 Figure 3 21 Restore Power 3 32 Table of Tables Table 1 hp AlphaServer ES47 ES80 GS1280 Documentation x Table 1 1 I O Drawers Supported by Model 1 3 Table 1 2 I O Upgrade Kit Contents 1 4 Ta...

Page 8: ...viii ...

Page 9: ...ade kit and the basic steps of the upgrade procedure Chapter 2 Prepare the system walks you through readying the system for upgrade including verifying the I O drawer location powering down and removing the side panel Chapter 3 Install and cable the I O drawer explains how to install an I O drawer and its associated hardware into cabinets for all models It details placement of the drawer and the i...

Page 10: ... Table 1 hp AlphaServer ES47 ES80 GS1280 Documentation Title Pages Size PDF HTML hp AlphaServer ES47 ES80 GS1280 Site Preparation 48 1 02 MB Y Y Installation Information 101 6 76 MB Y Y User Information 105 3 40 MB Y Y Server Management Tutorial Y Service Guide 525 6 9 MB Y Y AlphaServer Management Station Software Installation Guide 97 2 51 MB Y Y CLI Reference 117 0 30 MB Y Y SRM Console Referen...

Page 11: ...ster Drawer containing Up to seven 133 MHz PCI X slots An N 1 redundant power system A CD RW drive Two Ultra3 SCSI hot plug disk drive bays the disk drives must be ordered separately 4 High performance I O Expansion Drawer containing Up to eight 133 MHz PCI X slots An N 1 redundant power system An I O master drawer is a mandatory option for the GS1280 A separately ordered I O cable is required to ...

Page 12: ...0 GS1280 family supports from one to sixteen I O drawers or up to two high performance I O drawers the maximum depending on the type of system Figure 1 1 Example hp AlphaServer System ES80 Model 8 1 2 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 13: ... slots active Expansion ES80 Model 2 1 1 with 2 slots active Expansion ES80 Model 4 2 1 with 4 slots active Expansion ES80 Model 6 3 1 with 6 slots active Expansion ES80 Model 8 4 1 with 8 slots active Expansion GS1280 Model 8 8 2 with 8 slots active Master or Expansion GS1280 Model 16 16 2 with 8 slots active Master or Expansion GS1280 Model 32 16 2 with 8 slots active Master or Expansion GS1280 ...

Page 14: ...self tapping 5 5mm x 12mm 2 17 00442 02 Power cords 3m long 1 17 04991 04 Ground wire 8AWG 10 1 17 05097 04 Ethernet cable assembly 2 70 41067 01 Drawer latches 1 74 62379 01 Cable support rack 1 74 62381 01 Cable guide 2 74 62382 01 Shipping brackets 1 90 09984 18 Screw M5 x 0 8 x 12mm long 4 90 09984 19 Screws M4 x 0 7 x 8mm long pan head 12 90 09984 41 Screws Phillips pan head SEMS M6 x 18mm 12...

Page 15: ... Steps Step To do Resource 1 Check firmware levels Update to latest versions Backup important data FTP site listed above 2 Open your upgrade kit and check its contents Table 1 2 3 Shut down applications and operating systems in an orderly fashion Application and operating system guides 4 Remove power from the CPU drawer or partition associated with the I O drawer upgrade Wait 5 minutes so that any...

Page 16: ...1 6 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 17: ... O drawer upgrade Next make sure you have all the hardware components to proceed with the upgrade Then perform your system maintenance backing up important data and performing an orderly shut down of the CPU associated with the I O drawer upgrade Verify I O drawer location Check upgrade components Check I O cable length s Shut down system power Remove the side panel Prepare the System 2 1 ...

Page 18: ...ate the I O drawer upgrade In some cases you may need to order an expansion cabinet or other options The QuickSpecs will show you exactly where and the order in which I O drawers are installed for each type of system The latest QuickSpecs for North America are found here http h18000 www1 hp com products quickspecs North_America 10410 html QuickSpecs for other parts of the world can also be found t...

Page 19: ...into which you are going to install the I O drawer Table 2 1 Items Needed for I O Upgrade Amt Part Number Description 1 3X BA70A AA OR 3X BA70A BA OR 3X BA70B AA OR 3X BA70B BA I O master drawer OR I O expansion drawer OR High performance I O master drawer OR High performance I O expansion drawer 1 CK BA70A AA OR CK BA70B AA Accessory kit see Table 1 2 for content details 1 See Table 2 2 I O cable...

Page 20: ...Server systems The I O cable s you need for your upgrade depends on the distance between the I O drawer and its corresponding CPU drawer Determine the proper I O cable length s and have the cable s available for installation to proceed with this upgrade Table 2 2 I O Cable Lengths and Part Numbers For hp AlphaServer Length Order Number Part Number ES47 or ES80 3 5m 3X BNPCB 02 17 05036 02 GS1280 6...

Page 21: ... shutdown of the operating system Figure 2 1 Turn Off Power Table 2 3 OCP LED Table Amber LED Green LED Indication Off Off No Vaux On Off Vaux on bulk power off attention error inside the box Off On Vaux on bulk power on no errors On On Vaux on bulk power on attention error inside the box The top LED is amber and the bottom LED is green Prepare the System 2 5 ...

Page 22: ...power down the CPU partition associated with the I O module you are going to install by typing in the following MBM console command p off hp partition_name or c Execute the power off command using the OCP pushbuttons on the drawer that contains the target CPU 2 Wait for the orderly shutdown to complete 3 Unplug the CPU drawer from its power source 2 6 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upg...

Page 23: ...nt door e Pry the top panel off and lift it up Set it aside f For 34U and 41U cabinets remove the screws at the bottom of the side panel front and rear In this illustration it is the right side panel as viewed from the front If your cabinet is a 42U cabinet use your door key to unlock the side panels and then proceed g Starting at the bottom pry the side panel away from the cabinet Lift the side p...

Page 24: ...2 8 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 25: ...he drawer ID and power up Install the inner slides Determine hole locations for installation Loosely attach outer slides Attach cable retainer and grommet Install the I O drawer Install the cable support rack and the drawer latches Attach cable guides Attach cable support bracket on rear door Identify I O Connector on CPU drawer Connect I O cable s to CPU drawer s Route the I O cable s Connect I O...

Page 26: ...3 1 Install the Inner Slides Attach the inner halves of the slides to the I O drawer Figure 3 1 Installing the Inner Slides 3 2 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 27: ...he slides on the I O drawer as follows 1 Separate the slides so that their inner and outer halves are completely apart 2 On each side of the I O drawer use three M4 truss head machine screws to attach the inner half of the slide to the drawer Cabling 3 3 ...

Page 28: ...s for mounting the outer slides cable retainer and cable guides The hole locations vary according to the type of cabinet into which you are mounting the I O drawer Figure 3 2 Hole Locations for GS1280 Systems Front View 3 4 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 29: ...Figure 3 3 Hole Locations for ES47 and ES80 Systems Refer to Figures 3 2 and 3 3 to determine the hole locations and numbers for the outer slides rails and the cable retainer Cabling 3 5 ...

Page 30: ...3 3 Loosely Attach Outer Slides Loosely attach the outer halves of the slides to the cabinet rails Figure 3 4 Installing the Outer Slides 3 6 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 31: ... 8 on the front and rear vertical rails Be sure they are installed in the correct holes as specified in Section 3 2 2 Install each outer slide half using M6 x 18mm Phillips pan head screws 4 Do not completely tighten all the screws until you have installed the I O drawer in the cabinet see Section 3 5 Cabling 3 7 ...

Page 32: ...tainer and Grommet Then attach a cable retainer and grommet to the front right as viewed from the front cabinet vertical rail Figure 3 5 Installing the Cable Retainer 3 8 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 33: ...follows 1 Install cagenuts 2 on the front right vertical rails as viewed from the front making sure to use the correct hole numbers as specified in Section 3 2 2 Install the cable retainer using 18mm Phillips pan head screws 2 3 Install the grommet on the rail just below the cable retainer as shown in Figure 3 5 Cabling 3 9 ...

Page 34: ...e I O Drawer Tighten one outer slide half slide the I O drawer into the cabinet and then tighten the other outer slide half Figure 3 6 Installing the I O Drawer 3 10 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 35: ...t it can freely engage the inner slide half of the drawer on that side Do not tighten the screws for this slide half yet 3 At the rear of the cabinet lift and rest the front of the I O drawer onto the outer slide halves making sure the inner and outer halves of the slides are aligned With the drawer horizontally and vertically aligned with respect to the direction of installation carefully slide t...

Page 36: ...k and Drawer Latches Install the I O cable support rack and drawer latches on the rear of the I O drawer Figure 3 7 Installing Cable Support Rack and Drawer Latches Rear View 3 12 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 37: ...t rack into the hole at the rear of the I O drawer 3 Align the eyelets on the two sides of the cable support rack with the pre tapped holes in the I O drawer Also align a drawer latch with this hole on the outside of the I O drawer Use an M4 x 0 7 x 8mm screw to attach both the drawer latch and one side of the cable support rack to the I O drawer 4 Repeat steps 2 and 3 for the other side of the I ...

Page 38: ...the rear cabinet vertical rails The hole locations for mounting this hardware depends on the type of cabinet into which you are installing the I O drawer Figure 3 8 Attaching Cable Guides Rear View 3 14 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 39: ...on the rear cabinet rails as follows 1 For each bracket install a cagenut on the rear vertical rails making sure to use the correct holes as specified in Section 3 2 2 Install the cable retainer using an M6 x 18mm Phillips pan head screw Cabling 3 15 ...

Page 40: ... install a cable support bracket inside the cabinet back door For 42U cabinets skip this step installation of a rear door cable support bracket is not necessary Figure 3 9 Attaching Cable Support Bracket on Rear Door 3 16 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 41: ...the inside of the rear door as follows 1 Place the cable support bracket over any of the five horizontal welded supports on the inside back door 2 Secure the end of the cable support bracket to the inside back door by inserting the mounting bracket and tightening its screw Cabling 3 17 ...

Page 42: ...r Use the tables in Figure 3 10 to identify the cabinet drawer and slot number of the port to which your I O drawer will connect Figure 3 10 CPU Drawer I O Cable Connections for GS1280 3 18 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 43: ...on the CPU drawer connects to the I O riser IO7 in the drawer you are installing For example for a 16P GS1280 system with two I O expansion drawers already installed use the I O port connector of CPU5 in drawer 0 For ES47 and ES80 systems the tables are unnecessary because the connection path between a CPU and its I O drawer is fairly simple to determine Cabling 3 19 ...

Page 44: ...riate connector on the CPU drawer and drape the cable around the guides in the back of the drawer Figure 3 11 I O Cable Connections to CPU Drawer for GS1280 Figure 3 12 I O Cable Connections to CPU Drawer for ES47 or ES80 3 20 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 45: ... CPU drawer Remove the cable cover from the appropriate connector Attach one end of the I O cable to the connector Slide the drawer back into the cabinet For GS1280 systems drape the cables on the CPU drawer cable support trays as shown in Figure 3 11 For ES47 or ES80 systems see Figure 3 12 Cabling 3 21 ...

Page 46: ... the I O Cable s Route each I O cable from the CPU drawer to the I O drawer Use cable channels and supports where appropriate Figure 3 13 I O Cable Routing 3 22 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 47: ...opriate Figure 3 13 shows an example where a cable is routed from CPU drawer 3 slot 5 to I O drawer 0 the eighth I O drawer in the system in the expansion cabinet The specific route of the cable depends on the type of hp AlphaServer configuration you have Cabling 3 23 ...

Page 48: ...Connect each I O cable to an I O riser in the drawer and drape the cable appropriately around the guides Figure 3 14 I O Cable Draping GS1280 Figure 3 15 I O Cable Draping ES47 and ES80 3 24 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 49: ...wer as follows 1 From the rear of the cabinet slide out the I O drawer 2 Connect the I O cable to the I O riser connector on the back of the drawer 3 Drape the cables on the I O drawer guides as shown in Figures 3 14 and 3 15 Cabling 3 25 ...

Page 50: ...After installing the I O cable s plug the server management Ethernet cable into the server management HUB Then install the power cables to the PDU Figure 3 16 Ethernet Ground and Power Cables 3 26 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 51: ... drawer an M5 x 0 8 x 12mm screw as shown in Figure 3 16 Route the ground cable to the vertical rail and using a self tapping 5 5mm x 12mm screw attach the cable to the rear surface of the vertical rail as shown 3 Install the two power cords into the drawer and plug them into the cabinet s power distribution unit PDU as shown in Figure 3 17 If the cabinet has a second PDU installed for power redun...

Page 52: ...ide Panel Working from the side of the system return the side panel to the cabinet Figure 3 18 shows an example system Figure 3 18 Replacing the Side Panel Example 3 28 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 53: ...panel onto the cabinet frame Push the bottom in tightly 1 Insert and tighten the screws at the bottom of the panel front and rear For 42U cabinets use your system key to secure panels to rails 2 Press the top panel back onto the cabinet frame 3 Close the cabinet doors Cabling 3 29 ...

Page 54: ...re 3 19 Setting Drawer ID Each component must have its ID set according to its position in the cabinet If for example you have no PCI in the position associated with ID 6 you do not assign that ID to the drawer above it The drawer above retains ID 7 to indicate its physical position in the cabinet and the drawer below is ID 5 3 30 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 55: ...mple for ES80 System Position Set drawer ID Model PCI drawer 5th from bottom 4 PCI drawer 6th from bottom 5 PCI drawer 7th from bottom 6 PCI drawer 8th from bottom 7 Figure 3 20 ID Numbers Example for ES80 System Cabling 3 31 ...

Page 56: ...gure 3 21 Restore Power Table 3 2 OCP LED Table Amber LED Green LED Indication Off Off No Vaux On Off Vaux on bulk power off attention error inside the box Off On Vaux on bulk power on no errors On On Vaux on bulk power on attention error inside the box The top LED is amber and the bottom LED is green 3 32 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 57: ...that are not relevant to verifying this upgrade have been deleted They are represented in the example text as lines deleted Relevant sections are highlighted Your User Information CD has complete power up information 2 Commands that you input are shown in boldface type and underlined For example show cable Sections include Notify server management of new members Run show cable and verify configura...

Page 58: ...cTask Server management group is transitioning 2003 07 16 07 27 44 REC W trecTask Server management group is stable GRP W grp_Probe MBM PBM cab 01 drw 6 is not in the member list Z GRP W grp_Probe Use Set Membership add ca 1 dr 6 PBM SMG W trecTask Timed out waiting for response 314 from 10 254 5 1 10 0 0 1 10 254 5 1 ID 314 MISC Set Knob C REC E trecTask Failed to set SM environment variables Sta...

Page 59: ...ment group is stable Restore power to the system You will receive a series of error messages This is to be expected since the console is identifying a component not yet configured into the system network 1 After you return power the system begins its software power up Server management discovers any newly added drawers and reports them to you In this case server management has discovered a drawer ...

Page 60: ...SBB Cab Drw IOR Cab Drw IOP 0 2 0 0 0 0 1 3 0 0 1 6 1 4 0 0 1 4 1 5 0 0 1 2 1 6 0 0 1 0 Z 1 7 0 0 0 6 MBM MBM p on 2003 07 16 07 32 37 PCO I pco_01 Preparing to power on partition HP Default_HP 2003 07 16 07 32 47 PCO I pco_01 lines deleted AlphaServer Console V6 5 8 built on May 9 2003 at 10 10 56 P00 P00 sho config hp AlphaServer GS1280 7 1000 SRM Console V6 5 8 built on May 9 2003 at 10 10 56 P...

Page 61: ... AGP 35 0 5 vga lines deleted P00 To check your I O connection 1 Type in the command show cable 2 The system prints out a cabling diagram for the CPU IP cables and below that a table for the I O cables 3 This line indicates that there is a cable connection between the I O drawer drawer 6 in cabinet 1 and the CPU0 drawer drawer 1 in cabinet 0 4 Enter the command p on to power on 5 Once you have pow...

Page 62: ...itializing keyboard Starting secondary CPU 1 at address 400030000 Starting secondary CPU 2 at address 800030000 Starting secondary CPU 3 at address c00030000 initializing GCT FRU at 54c000 Initializing dqa dqb pka pkb pkc pkd pke pkf ega egb egc AlphaServer Console V6 4 12 built on Mar 6 2003 at 14 32 06 P00 1 Enter the command conn or connect X 2 Connects to partition using the CPU associated wit...

Page 63: ...ertain they have unique identifiers Issuing the Set Membership command should stop the broadcast message and enable server management to create a new group ID If your system keeps looping your drawers may have faulty connections to the system NAT box Each Ethernet connection should show two active LEDs If looping persists check the ID numbers on the OCP of each drawer Every drawer within any cabin...

Page 64: ... AC LEDs off AC input box broken AC LEDs off Power cords from AC input box to power supplies not plugged in or faulty Power supply LEDs off System does not power up and or the fans are off and or there is nothing on the console Power supplies broken Vaux LEDs off Power supply LEDs off Table 4 2 Troubleshoot Internal LAN Symptom Possible Cause Indicators Poor connections along the path from the con...

Page 65: ...em will cause 48V problems Any LAN problem Any OCP problem See the Vaux LAN and OCP sections of your Service CD Signal from the MBM to the power distribution panel on the subrack not good cables or cable connections Power supply LEDs off MBM failure Power supply LEDs off System or part of the system does not power up and or the fans are off More than one power supply broken Power supply LEDs off C...

Page 66: ...4 10 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...

Page 67: ...Verifying with Q Vet Use Q Vet to verify your newly upgraded system The following topics are covered here Run Q Vet Installing Q VET Running Q VET Reviewing Q VET Results De Installing Q Vet Verify with Q Vet 5 1 ...

Page 68: ... be installed and run separately on each partition Since Compaq Analyze is used to view Q Vet errors it is useful to install it prior to running Q Vet CAUTION Do not install the Digital System Verification Software DECVET on the system use Q Vet instead IVP Run only IVP scripts on systems that contain customer data or any other devices that must not be overwritten See the Q Vet Disk Testing Policy...

Page 69: ...this up either before or after Q Vet installation If during initialization Q Vet determines that the system does not have enough swap pagefile space it will display a message indicating the minimum amount needed If you wish to address the swap pagefile size before running Q Vet see the swap pagefile estimates on the Q Vet web site Verify with Q Vet 5 3 ...

Page 70: ...case of the file name may be different depending upon how it was stored on the system Also you may need to enclose the file name in quotation marks if a semi colon is used 5 Install the kit with the command setld l output 6 During the install if you intend to use the GUI you must select the optional GUI subset QVETXOSFxxx 7 The Q Vet installation will size your system for devices and memory It als...

Page 71: ...t was extracted by checking for the Successful decompression message 5 Use sys update vmsinstal for the Q Vet installation The installation will size the system for CPUs IO devices and memory If you do not intend to use the GUI you can answer no to the question Do you want to install Q Vet with the DECwindows Motif interface Otherwise choose all the default answers during the Q Vet installation Q ...

Page 72: ...load into the Q Vet process window Click the Start All button to begin IVP testing Command Line Interface vet nw Q Vet_setup execute Ivp scp Q Vet_setup start Note that there is a in front of the script name and that commands are case sensitive 5 3 2 OpenVMS Graphical Interface 1 From the Main Menu select IVP Load Script and select Long IVP the IVP tests will then load into the Q Vet process windo...

Page 73: ...i e until the slowest device has completed one pass of all tests typically 4 or 5 hours Optionally you can increase the IVP long run time by increasing the cyclecount 3 passes are recommended Two of the ways to do this are described If you wish to know more about Q Vet features like this see the training course at http learning1 americas cpqcorp net wbt cs127a ewb welcome htm After executing loadi...

Page 74: ...minate buttons stop and terminate commands After all exercisers report Idle the summary log is produced containing Q Vet specific results and statuses A If there are no Q Vet errors no system error events and testing ran to specified completion the following message will be displayed Q Vet Tests Complete Passed B Otherwise a message will indicate Q Vet Tests Complete Fail Run Compaq Analyze to rev...

Page 75: ...l_logs 4 Reboot the system You must reboot even if you decide to reinstall Q Vet If you do not reboot tuning configurations may not be set properly 5 5 2 OpenVMS 1 Command Q Vet to Stop Terminate and Exit 2 Execute the command sys manager qvet_uninstall This will remove Q Vet and restore system tuning modparams dat and the original UAF settings 3 Note log files are retained in sys specific sysmgr ...

Page 76: ...5 10 hp AlphaServer ES47 ES80 GS1280 I O Drawer Upgrade ...