SBXL52: Hardware Maintenance Manual and Troubleshooting Guide
System shutdown
Refer to the following tables when experiencing system shutdown related to voltage or temperature
problems.
System errors
System under recommended voltage for
+2.5v.
1.
Reseat blade server.
2.
Replace blade server.
System under recommended voltage for
+3.3v.
1.
Reseat blade server.
2.
Replace blade server.
System under recommended 5V fault.
1.
Reseat blade server.
2.
Replace blade server.
✏
NOTE
See “System” on page 104 to determine which components should be replaced by a field service
technician.
Message
Action
Internal Error CPU x fault
1.
Reseat:
a.
I/O Expansion Option
b.
Blade Storage Expansion option.
c.
IDE hard drive.
2.
Replace:
a.
Failing PCI adapter
b.
Microprocessor x.
c.
I/O Expansion Option.
d.
Blade Storage Expansion option.
e.
IDE hard drive.
f.
System board.
✏
NOTE
See “System” on page 104 to determine which components should be replaced by a field service
technician.
Message
Action