Symptom-to-FRU index
75
166-201-003 System Management:
Failed (I2C bus error(s) See SERVPROC
and DIAGS entries in event log.)
1.
I/O adapter
2.
System board
166-201-004 System Management:
Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
1.
SCSI storage expansion unit
2.
System board
166-201-005 System Management:
Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
1.
DIMMs
2.
Microprocessors
3.
System board
166-342-000 System Management:
Failed
(ASM adapter BIST indicate failed tests.)
1.
Ensure the latest firmware levels for Remote Supervisor
Adapter and BIOS are installed.
2.
Power down blade server and reseat it in chassis.
3.
Remote Supervisor Adapter.
166-400-000 System Management:
Failed (ISMP self test result failed tests: x
where x = Flash, RAM, or ROM.)
1.
Reflash or update firmware for ISMP.
2.
System board.
180-XXX-000 (Diagnostics LED failure)
•
Run diagnostics panel LED test for the failing LED.
180-XXX-001
(Failed front LED panel test)
1.
Front bezel with customer interface card
2.
System board
180-XXX-002
(Failed diagnostics LED panel test)
•
System board
180-XXX-003
(Failed system board LED test)
•
System board
180-XXX-005
(Failed SCSI backplane LED test)
1.
SCSI storage expansion unit
2.
System board
201-XXX-0nn
(Failed memory test.)
1.
DIMM Location slots 1-4 where nn = DIMM location.
✏
NOTE
nn 1=DIMM 1; 2=DIMM 2; 3=DIMM 3; 4=DIMM 4.
2.
System board.
201-XXX-999
(Multiple DIMM failure, see error text)
1.
See error text for failing DIMMs.
2.
System board.
202-XXX-001
(Failed system cache test)
1.
Microprocessor 1
2.
System board
202-XXX-002
(Failed system cache test)
1.
Microprocessor 2
2.
System board
217-198-XXX
(Could not establish drive parameters)
•
SCSI storage expansion unit
✏
NOTE
See “System” on page 104 to determine which components should be replaced by a field service
technician.
Error code/symptom
FRU/action