SBXL52: Hardware Maintenance Manual and Troubleshooting Guide
Temperature error messages
Power error messages
✏
NOTE
See “System” on page 104 to determine which components should be replaced by a field service
technician.
Message
Action
System over temperature for CPU x.
1.
Ensure that the system is being properly cooled; see “System
reliability considerations” on page 27
2.
Replace microprocessor x.
Blade Storage Expansion option over
recommended temperature.
1.
Ensure that the system is being properly cooled; see “System
reliability considerations” on page 27
2.
Replace the SCSI hard disk drives.
3.
Replace the Blade Storage Expansion option.
CPU x over temperature.
1.
Ensure that the system is being properly cooled; see “System
reliability considerations” on page 27
2.
Replace microprocessor x.
✏
NOTE
See “System” on page 104 to determine which components should be replaced by a field service
technician.
Message
Action
BSE +12V over recommended voltage
1.
Check SBCE power (see SBCE Hardware Maintenance Manual).
2.
Reseat blade storage expansion option.
3.
Replace blade storage expansion option.
BSE +12V under recommended voltage
1.
Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
BSE +5V over recommended voltage
1.
Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
BSE +5V under recommended voltage
1.
Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
BSE +18V over recommended voltage
1.
Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
BSE +18V under recommended voltage
1.
Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
BSE +3.3V over recommended voltage
1.
Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
BSE +3.3V under recommended voltage
1.
Reseat blade storage expansion option.
2.
Replace blade storage expansion option.