Symptom-to-FRU index
79
1301
(I2C cable to operator information panel
not found)
1.
Cable
2.
Operator information card
3.
Power switch assembly
4.
System board
1302
(I2C cable from system board to power-
on and reset switches not found)
1.
Cable
2.
Power switch assembly
3.
System board
1303
(I2C cable from system board to power
backplane not found)
1.
Cable
2.
Power supply
3.
System board
1304
(I2C cable to diagnostic LED board not
found)
1.
Power switch assembly
2.
System board
1762
(Hard disk configuration error)
1.
Hard disk drive.
2.
Hard disk drive cables.
3.
Run the Configuration/Setup Utility program.
4.
SCSI storage expansion unit.
5.
System board.
178X
(Fixed disk error)
1.
Hard disk drive cables.
2.
Run diagnostics.
3.
Hard disk drive.
4.
System board.
1800
(No more hardware interrupt available for
PCI adapter)
1.
Run Configuration/Setup to verify that the interrupt resource
settings are correct.
2.
Failing adapter (if installed).
3.
System board.
1962
(Drive does not contain a valid boot
sector)
1.
Verify that a startable operating system is installed.
2.
Run diagnostics.
3.
Hard disk drive.
4.
SCSI storage expansion unit.
5.
System board.
2400
(Video controller test failure)
1.
Verify that the keyboard/mouse/video select button LED on the
front of the blade server is on, indicating that the blade server is
connected to the shared SBCE monitor.
2.
Verify that the monitor is connected correctly to the SBCE unit.
3.
Video adapter (if installed).
4.
System board.
✏
NOTE
See “System” on page 104 to determine which components should be replaced by a field service
technician.
Error code/symptom
FRU/action